Introduction

The Pro Series 2200 A/C-D/C backup sump pump
system is battery-operated. It is designed as an
emergency backup system to support your
regular AC sump pump, and it will automatically
begin pumping if your main AC pump fails.
Should any malfunction or emergency occur that
involves the sump pump, the battery, or the AC
power, your Pro Series system will sound an
alarm.  A light on the display panel of the
control unit will indicate the cause of the alarm
and the corrective action.

If the main AC pump breaks or is unable to keep
up with all the incoming water, the Pro Series
pump is capable of running without discharging
the battery as long as the AC power is on.

The Pro Series Sump Pump System includes:

 

A control unit with a float switch and a
battery fluid level sensor

 

A pump with 1

1

2

” PVC pipe adapter

 

A plastic wire tie for mounting the float
switch

 

A battery box

 

A battery cap with a hole to accommodate
the fluid sensor

 

A battery filler bottle

You will also need to supply:

 

A  Pro Series 2200 Standby
Battery, or another deep cycle
battery 

 

1

1

2

” rigid PVC pipe and fittings 

 

PVC cement and primer

 

A union or a “Y” connector and
two (2) check valves depending
on the installation method you
use

 

Six (6) quarts of 1.265 specific
gravity battery acid

Replacement Parts 

Description

Part No

.

Pump

1011008

Float switch assembly

1020003

Fluid sensor assembly

1014001

Pipe adapter

1120002

Battery box

1113003

Battery cap with hole

1125000

Battery filler bottle

BFB-P

Call 800-991-0466, option 3 to
order parts.

System Specifications

Power supply requirements . . . . . . 115 volts AC
Pumping capacity . . . . . . . . . . 3500 GPH @ 0’
Pumping capacity . . . . . . . . . 2200 GPH @ 10’
Pump dimensions . . . . . . . . . . 7

5

8

H x 5

13

16

” W

Pump dimensions w/elbow . . . . . . 7

5

8

H x 9” W

Pump housing & strainer . . . . . .Non-corrosive,

will not rust

Pump . . . . . . . . . . . . . . . . . . . .Can run dry;

can be used in sumps with

water softener or laundry discharge

Float switch . . . . . . . . . . Independent; can be 

set at any level

Page 2

Control Unit

Battery Box

Cap

Wire Tie

Float
Switch

Pipe Adapter

Pump

Battery Wires

Fluid Sensor

For narrow sump pits you will need some
additional parts:

 

An “L” bracket at least 6 inches long.  (Preferably one that
will not rust.)

 

Two (2) stainless
steel hose clamps

 

One (1) stainless
steel screw (#8-32 x
3/4”), a matching
washer & nut

Battery

Filler

Bottle

Summary of Contents for Pro Series 2200

Page 1: ...ge to outside 4 Connection to existing discharge 5 Direct discharge for narrow sumps 6 Connection to existing discharge for narrow sumps 7 Battery Instructions 8 Control Unit Connections Positioning t...

Page 2: ...hese risks observe the following precautions Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery Have plenty of fresh water and soap...

Page 3: ...ndby Battery or another deep cycle battery 11 2 rigid PVC pipe and fittings PVC cement and primer A union or a Y connector and two 2 check valves depending on the installation method you use Six 6 qua...

Page 4: ...arrow pits the backup pump can be mounted above the main pump Try to fit the backup pump on the floor of the sump first Select the installation method that will best suit your needs from the diagrams...

Page 5: ...to an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the...

Page 6: ...If there is no check valve on the main AC pump one must be installed at this time Then install a Y connector above the check valve on the discharge pipe for the main AC pump 4 Secure the pump wire so...

Page 7: ...rest of the pipe and the details of each installation will vary Using sound plumbing practices try to route the discharge pipe to an exterior wall via the shortest path with the fewest turns More tur...

Page 8: ...the arrow pointing up or it will not prevent the backflow of water 4 b When a check valve is used drill a 1 8 hole in the 11 2 PVC pipe three inches 3 above the connection to the Pro Series pump Drill...

Page 9: ...ention Review the safety instructions on page 1 1 Remove the battery box top by pushing in the tabs on the front and back of the box and lifting up 2 Place the battery box on the floor Place the dry u...

Page 10: ...ile or any incoming rush of water 2 Connecting the pump Remove the security tag from the pump and plug the pump wires into the pump connector on the back of the control unit 3 Installing the battery f...

Page 11: ...protection Work in a well ventilated area Do not smoke or allow a spark or flame in the vicinity of the battery Avoid dropping metal tools on the battery If battery acid contacts eyes flush with water...

Page 12: ...the battery is relatively new and the battery alarm is activated before you replace the battery call the Glentronics service department The phone number is 800 991 0466 option 3 TO CLEAN THE BATTERY T...

Page 13: ...lence the Power failure alarm for 24 hours by pressing the GRAY button for 5 seconds The alarm will be silenced but the light will stay on The system will continue to operate while the power alarm is...

Page 14: ...ush the GRAY button to silence the alarm REPLACING THE PUMP Unplug the main AC pump when installing the backup pump to avoid electric shock Failure to do so could cause serious injury or death Review...

Page 15: ...is broken Backup pump is clogged PUMP WAS Possible Reasons The main AC pump failed because of a power outage The main AC pump is broken The float switch on the main pump is jammed or defective The mai...

Page 16: ...ed as evidence of the date of purchase and to establish warranty eligibility This warranty does not cover product problems resulting from handling liquids hotter than 120 degrees Fahrenheit handling i...