GLENTRONICS, INC. warrants to the original retail purchaser that all of its pump, switch, sensor, battery box and
control unit products are free from defective materials and workmanship for the period indicated below:

All parts and labor (excluding installation) for a period of 

three (3) years from the date of purchase

The defective product must be returned directly to the factory, postage prepaid with the original bill of sale or
receipt to the address listed below.  Glentronics, Inc., at its option, will either repair or replace the product and
return it postage prepaid.

CONDITIONS

The unit must be shipped freight prepaid, or delivered, to Glentronics, Inc. to provide the services described
hereunder in either its original carton and inserts, or a similar package affording an equal degree of protection.

The unit must not have been previously altered, repaired or serviced by anyone other than Glentronics, Inc., or its
agent; the serial number on the unit must not have been altered or removed; the unit must not have been subject
to accident, misuse, abuse or operated contrary to the instructions contained in the accompanying manual.

The dealer’s dated bill of sale, or retailer’s receipt, must be retained as evidence of the date of purchase and to
establish warranty eligibility.

This warranty does not cover product problems resulting from handling liquids hotter than 120 degrees Fahrenheit,
handling inflammable liquids, solvents, strong chemicals or severe abrasive solutions; normal wear; user abuse;
misuse, neglect, improper maintenance, commercial or industrial use; improper connections or installation;
damages caused by lightning strikes, excessive surges in AC line voltage, water damage to the controller, other acts
of nature, or failure to operate in accordance with the enclosed written instructions.

GLENTRONICS, INC. WILL NOT BE LIABLE FOR ANY INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES FOR BREACH
OF ANY EXPRESS OR IMPLIED WARRANTIES ON THIS PRODUCT.  SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF CONSEQUENTIAL OR INDIRECT DAMAGES, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.  THIS
EXPRESS WARRANTY SHALL BE EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, WRITTEN OR ORAL, EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE.  THE CUSTOMER’S EXCLUSIVE REMEDY FOR BREACH OF THIS WARRANTY, OR OF ANY IMPLIED WARRANTY
NOT EXCLUDED HEREIN, SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT.

For information or service contact:

Glentronics, Inc.

640 Heathrow Drive

Lincolnshire, IL 60069

800-991-0466

Model # PHCC-2200      Serial # _____________________   Purchase Date__________________

Summary of Contents for Pro Series 2200

Page 1: ...ge to outside 4 Connection to existing discharge 5 Direct discharge for narrow sumps 6 Connection to existing discharge for narrow sumps 7 Battery Instructions 8 Control Unit Connections Positioning t...

Page 2: ...hese risks observe the following precautions Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery Have plenty of fresh water and soap...

Page 3: ...ndby Battery or another deep cycle battery 11 2 rigid PVC pipe and fittings PVC cement and primer A union or a Y connector and two 2 check valves depending on the installation method you use Six 6 qua...

Page 4: ...arrow pits the backup pump can be mounted above the main pump Try to fit the backup pump on the floor of the sump first Select the installation method that will best suit your needs from the diagrams...

Page 5: ...to an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the...

Page 6: ...If there is no check valve on the main AC pump one must be installed at this time Then install a Y connector above the check valve on the discharge pipe for the main AC pump 4 Secure the pump wire so...

Page 7: ...rest of the pipe and the details of each installation will vary Using sound plumbing practices try to route the discharge pipe to an exterior wall via the shortest path with the fewest turns More tur...

Page 8: ...the arrow pointing up or it will not prevent the backflow of water 4 b When a check valve is used drill a 1 8 hole in the 11 2 PVC pipe three inches 3 above the connection to the Pro Series pump Drill...

Page 9: ...ention Review the safety instructions on page 1 1 Remove the battery box top by pushing in the tabs on the front and back of the box and lifting up 2 Place the battery box on the floor Place the dry u...

Page 10: ...ile or any incoming rush of water 2 Connecting the pump Remove the security tag from the pump and plug the pump wires into the pump connector on the back of the control unit 3 Installing the battery f...

Page 11: ...protection Work in a well ventilated area Do not smoke or allow a spark or flame in the vicinity of the battery Avoid dropping metal tools on the battery If battery acid contacts eyes flush with water...

Page 12: ...the battery is relatively new and the battery alarm is activated before you replace the battery call the Glentronics service department The phone number is 800 991 0466 option 3 TO CLEAN THE BATTERY T...

Page 13: ...lence the Power failure alarm for 24 hours by pressing the GRAY button for 5 seconds The alarm will be silenced but the light will stay on The system will continue to operate while the power alarm is...

Page 14: ...ush the GRAY button to silence the alarm REPLACING THE PUMP Unplug the main AC pump when installing the backup pump to avoid electric shock Failure to do so could cause serious injury or death Review...

Page 15: ...is broken Backup pump is clogged PUMP WAS Possible Reasons The main AC pump failed because of a power outage The main AC pump is broken The float switch on the main pump is jammed or defective The mai...