background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

MPR-414FS 
MPR-414F 

Series

 

Please read the operating instructions carefully before using this product, and keep the operating 

instructions for future use. 

See page 33 for all model numbers.

 

Operating Instructions

 

Pharmaceutical Refrigerator 

MPR-414F 

Summary of Contents for MPR-414F Series

Page 1: ...es Please read the operating instructions carefully before using this product and keep the operating instructions for future use See page 33 for all model numbers Operating Instructions Pharmaceutical...

Page 2: ......

Page 3: ...OF FREEZER 15 DEFROSTING 16 ALARM TEMPERATURE SETTING 17 SETTING OF ALARM RESUME TIME 19 REMOTE ALARM TERMINAL 19 ALARMS AND SAFETY FUNCTIONS 20 ROUTINE MAINTENANCE Cleaning 21 Replacement of lamp 22...

Page 4: ...ent of performance or functions Contact our sales representative or agent if any page of the operating instructions is lost or page order is incorrect Contact our sales representative or agent if any...

Page 5: ...in serious injury or death CAUTION Failure to observe CAUTION signs could result in injury to personnel and damage to the unit and associated property Symbol shows This symbol means caution This symbo...

Page 6: ...wer supply outlet is not grounded it will be necessary to install a ground by qualified engineers Never ground the unit through a gas pipe water main telephone line or lightning rod Such grounding may...

Page 7: ...shock or fire When removing the power supply plug from the power supply outlet grip the power supply plug not the cord Pulling the power supply cord may result in electric shock or fire by short circu...

Page 8: ...may cause a heat or ignition Never store corrosive substances such as acids or alkalis in the unit except in a sealed container These may be detrimental to health and may cause corrosion of internal c...

Page 9: ...C Maximum relative humidity 80 for temperature up to 31 o C decreasing linearly to 50 relative humidity at 40 o C Mains supply voltage fluctuations up to 10 of the nominal voltage Transient overvoltag...

Page 10: ...8 REFRIGERATOR COMPONENTS Refrigerator unit MPR 414F with drawer rack optional component 3 7 4 6 4 5 10 10 2 1 11 14 13 12 17 15 Freezer Refrigerator 16 8 9...

Page 11: ...degree Take care not to change the pillar angle 9 Protective sheet The stored material may be frozen if it is put on the chamber bottom directly Always put the sheet in the refrigerator compartment up...

Page 12: ...ock can be selected by pressing this key in the key lock mode 7 Digit shift key Pressing this key in set mode causes the changeable digits to move Key lock is activated by pressing this key for more t...

Page 13: ...tion site is not adequate this may result in injury from the unit falling or tipping over Select a level and sturdy floor for installation This precaution will prevent the unit from tipping Improper i...

Page 14: ...level Fig 1 3 Fixing the unit Two fixtures are attached to the rear of the frame Fix the frame to the wall with these fixtures and rope or chain Fig 2 4 Ground earth WARNING Use a power supply outlet...

Page 15: ...o the chamber to minimize the temperature rise Note Fix the shelves securely Place items on the shelves and leave a space between the walls of the cabinet and the contents to allow air circulation Do...

Page 16: ...the figure of the current digit 5 Press set key SET The value is stored in memory and the current refrigerator temperature is displayed 6 Select freezer FREEZ by pressing display select key REF FREEZ...

Page 17: ...yed Note Key lock can be set any time when the current refrigerator or freezer temperature is displayed DEFROSTING OF FREEZER Table 3 below shows the procedure for defrosting of freezer or stopping th...

Page 18: ...rost once a week with 2 o C setting in the ambient of 35 o C and 80 R H The chamber temperature goes up to approximately 10 o C temporarily during defrosting Freezer Natural defrost by stopping operat...

Page 19: ...en the chamber temperature deviates from set temperature by more than 3 o C Note The temperature alarm setting at the factory is as follows High temp alarm Low temp alarm Refrigerator Set temp 5 o C S...

Page 20: ...umerical value shift key Pressing the key leads the change of flashed digit Pressing the key shifts up the figure of the current digit 6 Press the set key SET The value is stored in memory and the cur...

Page 21: ...rent digit 4 Press the set key SET The current set value is displayed and the second digit of the temperature display flashes 5 Set to 020 by using numerical value shift key Pressing the key shifts up...

Page 22: ...event of a power failure disconnection of power supply plug from the outlet or turn off of power switch Remote alarm is activated Door alarm When the door is open Door check lamp is lit Intermittent t...

Page 23: ...osed with the detergent When a diluted neutral dishwashing detergent is used wipe the cabinet or accessories thoroughly with a cloth soaked in clean water Then wipe the cabinet or accessories unit wit...

Page 24: ...2 To remove the lamp cover hold the both sides of the cover with flexure and push it backward 3 Remove the bulb from the socket by turning it to counterclockwise Caution Take care not to injure the f...

Page 25: ...e unit for several hours When unit does not get cold enough The air exhaust vent is blocked by refrigerator contents A large amount of warm product was put in the unit There is any heat sources in the...

Page 26: ...elektromos s elektronikus berendez sek hullad kainak rtalmatlan t s r l h ztart sok Ha ez a szimb lum szerepel a term keken s vagy a mell kelt dokumentumokon az elhaszn lt elektromos s elektronikus t...

Page 27: ...otros pa ses no pertenecientes a la Uni n Europea Este s mbolo s lo es v lido en la Uni n Europea Si desea desechar este producto p ngase en contacto con las autoridades locales o con su distribuidor...

Page 28: ...oor de volksgezondheid en het milieu die anders kunnen ontstaan door een onjuiste verwerking van afval Neem contact op met uw gemeente voor meer informatie over het dichtstbijzijnde inzamelingspunt of...

Page 29: ...venditore e chiedere informazioni sul metodo corretto di smaltimento Informasjon for brukerne om kassering av elektrisk og elektronisk utstyr private husholdninger N r et produkt og eller medf lgende...

Page 30: ...ont right of top panel or Fixing enclosed with the recorder Lower right of front panel In the case of no use of MTR 4015LH MPR S30 MTR 4015LH For freezer Lower right of front panel MPR S30 MTR G3504A...

Page 31: ...with the enclosed clips Fig 3 6 Arrange the capillary tube so that it cannot disturb the shelves Take care not to crush the tube when it is bent 7 Make a cut on the rubber cap and pass the capillary...

Page 32: ...nent by using the enclosed screws Fig 2 5 Mount the recorder fixing with recorder to the mounting space for a temperature recorder Fig 3 6 Route the recorder sensor and capillary tube as shown in the...

Page 33: ...nclosed with the recorder fixing Fig 2 5 Remove the connector cover Then connect the power connector on the temperature recorder to the connector on the unit side Fig 3 WARNING Always disconnect the p...

Page 34: ...Condenser Wire and tube Refrigerator Rear side condenser Freezer Refrigerant R 134a HFC 134a Refrigerator R 407D Freezer Defrosting Cycle defrost and forced defrost Refrigerator Natural defrost by st...

Page 35: ...r consumption 375 W 390 W 425 W 350 W 370 W 350 W 365 W Note The unit with CE mark complies with EU directives Product name Pharmaceutical Refrigerator MPR 414FS Model number MPR 414FS PT MPR 414FS PA...

Page 36: ...ontamination of the unit Unit interior No contamination Yes No Decontaminated Yes No Contaminated Yes No Others 3 Instructions for safe repair maintenance disposal of the unit a The unit is safe to wo...

Page 37: ......

Page 38: ......

Page 39: ......

Page 40: ...Printed in Japan LDCL037200 1 S0418 11118 1 1 1 Sakada Oizumi machi Ora gun Gunma 370 0596 Japan PHC Corporation 2018...

Reviews: