TROUBLESHOOTING 

   
If the unit malfunctions, check out the following before calling for service. 
 

Malfunction Check/Remedy 

If nothing operates even 
when plugged in 

 The unit is not connected to the power supply properly. 

 The capacity and voltage of power supply is not sufficient. 

 There is a power failure. 

 The circuit breaker on the supply circuit is activated. 

 The fuse on the supply circuit is blown. 

The alarm device is 
activated during operation

 

 The unit is not connected to the power supply properly. 

 The capacity and voltage of power supply is not sufficient. 

 There is a power failure. 

 The circuit breaker on the supply circuit is activated. 

 The fuse on the supply circuit is blown. 

 The chamber temperature setting was changed. 

 The door was kept opened for a long time. 

 The containers of high temperature (load) were put in the chamber. 

 The door is opened. 

No key operation is 
available 

 The key lock is set in ON (L 1). 

 Set the key lock in OFF (L 0). 

During the setting mode, 
the mode returns to the 
temp. display mode 

 The setting mode returns to the temperature display mode 

automatically when 90 seconds has passed without any key operation 
(auto-return function). 

Noisy 

 The floor is not sturdy. 

 The installation location is not level. 

 The freezer is tilted. 

 The cabinet contacts the surrounding wall. 

When chamber does not 
get cold enough

 

 A large amount of items or warm product was put in the chamber. 

 The door is frequently opened. 

 The chamber temperature setting is high. 

 The unit is in direct sunlight. 

 The unit is not installed in the installation location specified in this 

operating instructions. 

 The ventilation around the unit is blocked. 

 There is a nearby heat source. 

 The ambient temperature is too high. 

 The allowable ambient temperature is between 5 

o

C and 30 

o

C. 

 The stored items are too much. 

 The access port is not covered. 

 The access port should be covered with the insulation and rubber 

caps when no use. 

 The door seal is damaged. 

 If it is damaged, contact our sales representative or agent for 

replacement. 

 Any foreign substance is located between door gaskets. 

Note: 

If the malfunction is not eliminated after checking the above items or the malfunction is not shown in the 
above table, contact our sales representative or agent. 
 
 

 

Summary of Contents for MDF-U5412

Page 1: ...U5412 Please read the operating instructions carefully before using this product and keep the operating instructions for future use See page 26 for model number Operating Instructions Biomedical Free...

Page 2: ......

Page 3: ...14 ALARM TEMPERATURE SETTING P 15 SETTING OF ALARM RESUME TIME P 16 DURING AFTER POWER FAITURE P 17 REMOTE ALARM TERMINAL P 18 ALARMS SAFETY FUNCTIONS P 19 ROUTINE MAINTENANCE P 20 Cleaning of cabine...

Page 4: ...ating instructions are subject to change without notice for improvement of performance or function Contact our sales representative or agent if any page of the operating instructions is lost or the pa...

Page 5: ...s could result in injury to personnel and damage to the unit and associated property Symbol shows This symbol means caution This symbol means an action is prohibited This symbol means an instruction m...

Page 6: ...wer supply outlet is not grounded it will be necessary to install a ground by qualified engineers Never ground the unit through a gas pipe water main telephone line or lightning rod Such grounding may...

Page 7: ...shock or fire When removing the power supply plug from the power supply outlet grip the power supply plug not the cord Pulling the power supply cord may result in electric shock or fire by short circu...

Page 8: ...r improper insertion may cause a heat or ignition Never store corrosive substances such as acid or alkali in this unit if the container cannot be sealed These may cause corrosion of inner components o...

Page 9: ...40 o C Maximum relative humidity 80 for temperature up to 31 o C decreasing linearly to 50 relative humidity at 40 o C Mains supply voltage fluctuations up to 10 of the nominal voltage Transient overv...

Page 10: ...8 FREEZER COMPONENTS 12 Back side 11 14 15 13 1 9 2 8 3 4 7 5 6 10 Space for interface board...

Page 11: ...the floor 8 Door latch To lock the outer door turn this latch downward A padlock is also available 9 Storage container Made of styrol resin Be careful not to damage the storage container by a scraper...

Page 12: ...tively 4 Digit shift key Pressing this key in the setting mode causes the changeable digit to shift key lock setting mode is led by pressing this key for more than 5 seconds in the temperature display...

Page 13: ...n or noise WARNING Install the unit on a sturdy floor If the floor is not strong enough or the installation site is not adequate this may result in injury from the unit falling or tipping over Select...

Page 14: ...Stretch the leveling feet by rotating them to contact them to the floor Ensure the unit is installed horizontally Fig 1 3 Fixing the unit Two fixtures are attached to the rear of the frame Fix the fra...

Page 15: ...on the control panel and buzzer sounds if the battery switch is off Make sure to turn on the battery switch 6 After confirming the above you can put articles into the biomedical freezer chamber in a s...

Page 16: ...s 30 o C The setting mode returns to the temperature display mode automatically when 90 seconds has passed without any key operation In this case any setting before pressing set key SET is not memoriz...

Page 17: ...4 Press set key SET The current setting is displayed and the first digit is flashed 5 Scroll the figure to 005 by using digit shift key and numerical value shift key When pressed the figure of settabl...

Page 18: ...he first digit is flashed 3 Set the figure to F25 with the digit shift key and numerical value shift key When pressed the settable digit is shifted When pressed the figure of settable digit changes 4...

Page 19: ...e alarm would not be activated at power failure if the battery is not replaced regularly Contact our sales representative or agent for the replacement of battery Operation check after recovery from th...

Page 20: ...capacity is DC 30 V 2 A Contact output Contact output Terminal Normal status Abnormal status Between COM and N O open close Between COM and N C close open Note The remote alarm is stopped by pressing...

Page 21: ...tone Remote alarm Condenser temp abnormality In the event of failure of fan motor for cooling the compressor When the ambient temperature exceeds the usable environmental condition etc E10 and chambe...

Page 22: ...roduct is refrigerated by the direct cooling When it uses for a long time frost appears on the chamber wall side It cannot be cooled down when there is much amount of frost Use the scraper provided fo...

Page 23: ...arm function flash of alarm lamp sound of buzzer will not operate when the battery for power failure alarm is flat The alarm lamp flashed and the buzzer sounds by the battery for power failure alarm T...

Page 24: ...tting mode returns to the temperature display mode automatically when 90 seconds has passed without any key operation auto return function Noisy The floor is not sturdy The installation location is no...

Page 25: ...wers the product you have purchased Please call 1 800 8 BATTERY for information on how to recycle this battery L appareil que vous vous tes procur est aliment par une pile au nickel m tal hydrure NiMH...

Page 26: ...sales representative or agent For the usage of the temperature recorder also refer to an installation sheet enclosed with the temperature recorder Main specifications of temperature recorder MTR G85C...

Page 27: ...display between 50 o C and 50 o C Temperature sensor Thermistor sensor Temperature alarm Flash of digital indicator and alarm lamp Buzzer Remote alarm Accessories 1 set of key 1 scraper 6 small basket...

Page 28: ...ber MDF U5412 PB Cooling performance 40 o C ambient temperature 30 o C no load Temperature control range 20 o C to 40 o C Rated voltage AC 220 V Rated frequency 50 Hz Rated power consumption 205 W Noi...

Page 29: ...the unit Unit interior No contamination Decontaminated Contaminated Others 3 Instructions for safe repair maintenance disposal of the unit a The unit is safe to work on b There is some danger see bel...

Page 30: ......

Page 31: ......

Page 32: ...Printed in Japan LDCL034900 0 S0418 0 PHC Corporation 2018 1 1 1 Sakada Oizumi machi Ora gun Gunma 370 0596 Japan...

Reviews: