Phason
29 / 98
34740001
Temperature averaging and zone control
If you have more than one temperature sensor assigned to control a zone, Supra Touch automatically
averages the temperature readings it receives. Temperature averaging provides a more balanced, overall
temperature for a zone.
If there are no functioning temperature sensors, Supra Touch controls the
equipment as if the master set point for the zone is the actual temperature.
Replace damaged temperature sensors as soon as possible. If a temperature
sensor is damaged, disable it until you can replace it with a new one.
Influencers / modifiers
Influencers, also called modifiers, are sensors that can modify zone control. For example, you can use a
humidity sensor to modify ventilation and increase ventilation when humidity levels are too high. For more
information, read
To configure inputs
1.
Press the
Menu
and then
Configuration
.
2.
Press
Sensors
.
3.
Press the type of input you want to configure.
4.
Press the input you want to configure.
The Sensor Configuration screen displays.
Name:
a)
Press the button beside Name and then press
Rename
.
b)
Press
Reset
and then type the new name.
c)
When finished, press
Confirm
to save the name
and return to the previous screen.
Function:
Press the button beside Function. If there only one
option available, it will be enabled. If there is more
than one option available, select the one you want
from the list.
Control zones:
Sensors connected to inputs TEMP 1-4 on the bottom board or TEMP on the display board can be
used to control zones. Other inputs will not display this option. Select each zone the sensor will
control.
Influence zones:
All sensors can be used to influence control zones. If the sensor will influence zones, select the
zones.
5.
Press
Save
when you are finished.