PFT ZP 3 L MULTIMIX Overview – Operation – Spare Parts Lists
Measures to be taken in the event of a power failure
36
2016-07-04
34 Measures to be taken in the event of a power failure
34.1 Discharging mortar pressure
2
1
3
4
Fig. 59: Power failure
1. Check the mortar pressure gauge (1) to see if the pressure has
fallen to “0 bar”. If necessary, discharge any mortar pressure
by unscrewing the flanged nuts (2) slightly.
2. Then tighten the flanged nuts again.
DANGER!
Overpressure on the machine!
When opening machine components, these can fly
open in an uncontrolled manner and injure the
operator.
– Only open the machine if the pressure has
fallen to “0 bar”.
DANGER!
Danger of injury due to leaking mortar!
Escaping mortar can lead to injuries to the eyes
and face.
Therefore:
Never look into the spraying gun.
Always wear protective goggles.
Always position the machine so that you
cannot be hit should mortar escape.
NOTE!
In the event of a prolonged power failure, the ZP
3 L and the material hoses should be cleaned
immediately.
NOTE!
The ZP 3 L is equipped with a starting lock. In the
event of a power failure, the system must be
started as follows.
3. Turn the main switch (3) to the “0” position, and then turn it to
the “I” position.
4. Press the green push button (4) to switch the control voltage
“ON”.
5. The ZP 3 L starts up again.