PFT ZP 3 L MULTIMIX Overview – Operation – Spare Parts Lists
Mortar pressure gauge
2016-07-04
25
23 Mortar pressure gauge
Fig. 24: Mortar pressure gauge
DANGER!
Operating pressure too high!
Machine components can fly open in an
uncontrolled manner and injure the operator.
– Do not operate the machine without the mortar
pressure gauge.
– Only use mortar hoses with a permissible
operating pressure of at least 40 bar.
– The burst pressure of the mortar hose must be
at least 2.5 times the operating pressure.
24 Checking the direction of rotation of the MULTIMIX
Fig. 25: Checking the direction of rotation
1. Check the direction of rotation of the mixing arms.
2. The mixing unit runs anticlockwise.
1
2
Fig. 26: ZP 3 L Switching on
1. Check whether the connector plug MULTIMIX (1) is connected
to the control box.
2. Switch on the ZP 3 L using the main reversing switch (2).
3. If the direction of rotation is incorrect, change the direction of
rotation using the MULTIMIX main reversing switch (3).
4
3
Fig. 27: Changing the direction of rotation
4. Turn the main reversing switch (3) on the MULTIMIX to the “I”
position.
NOTE!
If the direction of rotation is incorrect:
The main reversing switch is locked in the zero
position by pushing the selection switch (4) to the left
or right. This defines the direction of rotation. If the
switch is set to the left, the switch can be reset to
zero but is blocked for the right-side position.
6. Switch off the MULTIMIX again at the main reversing switch.