7 WATER SUPPLY CONNECTIONS
Connect water Supply Lines (
7A
) to Faucet Inlets (
7B
). Hot water supply lines go into
left inlet. Cold water supply lines go into right inlet. (
Supply lines are not included
).
Please follow manufacturer’s instructions when installing supply lines.
8 UNIT START UP
Turn on hot and cold water supplies, and check for leaks above and below the sink.
9 FAUCET FUNCTIONS
COLD valve: close-counterclockwise, open-clockwise; HOT valve: close-clockwise,
open-counterclockwise. The Spout (
9A
) can be rotated around the Faucet Body in
any direction.
Note:
Flush faucet before turning on valve (
see step 11
).
10 SIDE SPRAY OPERATION
The Side Spray (
10A
) can be pulled forward to spray water in any direction. To activate
the Side Spray, press the Toggle Button (
10B
) located on the back of the Side Spray (
10A
).
11 FLUSHING & AERATOR CLEANING
After installation is complete, remove Aerator Housing (
11A
). Turn Valves (
11B
) on
and allow both hot and cold water to run for at least one minute each. While water is
running, check for leaks. To clean the aerator, disassemble Aerator Housing (
11A
) by
separating the Aerator Shell (
11C
), Basket (
11D
) and Washer (
11E
). Once parts have
been cleaned, reassemble by reversing steps.