PREPARATION & BUILDING DESIGN Cont...
The Vent inlet pipe should be located on the North side and it is recommended that north facing solar
transfer be used where possible to provide heat for the Rota-Loo and Excess Liquid evaporation where
installed.
• If your Maxi is going to have a solar powered fan there needs to be northern exposure and a clear view
of the sun.
• If your Maxi is going to have an evaporative trench to handle any excess liquid your site needs to have
a patch of level diggable ground adjacent to the building. If your building is going to have a suspended
concrete floor it is best not to use the chutes as forms when pouring the slab on decking. Plan to cast
the holes about 30mm larger. They can always be grouted later.
•
The drawing below shows a typical Maxi Rota-Loo installation with Excess Liquid Tank and Soltran
enclosure.
5
RL2000 Maxi
Chamber &
Buckets
Air Inlet for
Excess Liquid
Tank
Excess Liquid
Tank unit
Fan Housing
for Excess
Liquid Tank
Air Inlet for
RL2000 Maxi
Toilet Cubicle
Vent pipes for Excess Liquid
Tank and RL2000 Maxi