Operating Instructions
MILOMAT
laboratory mill
© 2017 Pfeuffer GmbH
Revision 1
Page 29 of 32
Changing the outlet
8.7
Figure 33: Outlet, complete
Loosen the two lens head screws (item 5) in the outlet from below.
Remove the outlet.
Fasten the new outlet, see figure 33.
Item Designation
1
Outlet
2
Damping rubber
3
Holding plate
4
Fan washer
5
Lens head screw M3x12
Checks
8.8
At the end of the work, check the following:
The work carried out is complete.
Check the wiring in the housing for kinks, chafing or charred points.
Damage on the covers or insulation.
Check that no tools have been left in or on the machine.
All subassemblies function correctly in setup or manual mode.
If all functions are correct, the machine can be handed over to the owner.
NOTE
Following cleaning, maintenance or exchanging wearing parts, check that all safety
devices are functioning correctly.