94
Step
no.
Display / Function
Sewing machine
Visual Check / action
at machine
Nominal
machine display
Remarks
42. Self-test model 2014 and 2024
1
Machine without needle
Master switch off
2
Press pattern mirroring
key and actuate master
switch at the same time.
TE
After releasing both keys,
you have to wait for a
period of 3 secs. which is
shown on the display.
If no display use faultfin-
ding chart.
3
Visual check:
All indicator elements
must flash 5 times
All indicator ele-
ments flash
Visual check negative:
change respective subas-
sembly.
If one of the modules
returns an error, "ER" will
appear on the display
and the following tests
will be skipped.
4
KY
(keytest)
0=sewing on buttons
1=straight stitch
2=stretch triplestraight
stitch
3=zigzag stitch
4=elastic stitch
5=blind stitch
6=elastic blind stitch
7=overlock stitch
8=faggoting stitch
9=buttonhole
10=prog. sel. key left
11=prog. sel. key right
12=stitch width -
13=stitch width +
14=stitch length
15=stitch
16=correction -
17=corr
18=reverse key
Actuate the key shown
The next key to
be actuated is
shown
A time span of approx.
12 secs is planned for
each key actuation.If the
key is not pressed within
this time span, the next
key to be actuated is dis-
played and the non-
actuation of the key is
registered as an error and
displayed at the end of
the program.
Summary of Contents for EXPRESSION 2014
Page 1: ...Service Manual 1st edition November 2002 expression 2014 2024 2034 2044 german engineering...
Page 2: ...Leerseite...
Page 18: ...16 Notes...
Page 27: ...25...
Page 33: ...31 Cross check Turn the handwheel and check for clearance of 0 2 mm...
Page 35: ...33...
Page 39: ...37...
Page 43: ...41...
Page 51: ...49 Notes...
Page 59: ...57...
Page 61: ...59...
Page 63: ...61...
Page 65: ...63...
Page 69: ...67...
Page 73: ...71...
Page 81: ...79...
Page 83: ...81...
Page 85: ...83...
Page 87: ...85...
Page 89: ...87...
Page 93: ...91...
Page 109: ...107...
Page 111: ...109 Notes...