84
36. Changing the top stepping motor
Note:
The stepping motor for sideways needle bar movement is only exchanged complete.
Removal:
●
Remove mains lead.
●
Remove detachable work support.
●
Remove the housing according to the service manual.
●
Remove circlip 97 on zigzag stepping motor 46 (fig. 105).
●
Disengage connecting rod 99 and the tooth segment of zigzag stepping motor 46.
●
Unscrew and remove both fastening screws 45.
●
Lift zigzag stepping motor 46 upwards out of the retainer in the direction of the arm shaft.
●
Remove the zigzag stepping motor to the front, out of the housing.
Fitting:
●
Install zigzag stepping motor 46 in the housing.
●
Pull power cable downward.
●
Insert and tighten both fastening screws 45 (fig. 106).
●
Insert the pin of connecting rod 99 in the hole of the tooth segment.
●
Attach circlip 97.
●
Mount the housing according to the service manual.
Note:
Having exchanged the zigzag stepping motor for sideways needle movement, adjustment of the needle
in the needle hole, section 9 must be repeated.
●
Carry out a check of all functions.
●
Carry out an electrical safety test in accordance with VDE 0701 using testing appliance Metra-
watt 5013.
Summary of Contents for EXPRESSION 2014
Page 1: ...Service Manual 1st edition November 2002 expression 2014 2024 2034 2044 german engineering...
Page 2: ...Leerseite...
Page 18: ...16 Notes...
Page 27: ...25...
Page 33: ...31 Cross check Turn the handwheel and check for clearance of 0 2 mm...
Page 35: ...33...
Page 39: ...37...
Page 43: ...41...
Page 51: ...49 Notes...
Page 59: ...57...
Page 61: ...59...
Page 63: ...61...
Page 65: ...63...
Page 69: ...67...
Page 73: ...71...
Page 81: ...79...
Page 83: ...81...
Page 85: ...83...
Page 87: ...85...
Page 89: ...87...
Page 93: ...91...
Page 109: ...107...
Page 111: ...109 Notes...