Care and maintenance
10 - 3
10
12
0
6
4
2
8
16
14
100
50
150
0
200
230
10
12
0
6
4
2
8
16
14
100
50
150
0
200
230
Fig. 10 - 03
10
.04
Cleaning the air filter of the air-filter/lubricator
Switch the machine off!
Disconnect the air hose at the
air-filter/lubricator.
To drain water bowl
1
:
●
Water bowl
1
drains itself automatically
whe the compressed-air hose is discon-
nected from the air-filter/lubricator.
Cleaning filter
2
:
●
Unscrew water bowl
1
.
●
Take out filter
2
.
●
Clean filter
2
with compressed air or iso-
propyl alcohol (part No. 95-665 735-91).
●
Screw in filter
2
and screw on water
bowl
1
.
Fig. 10 - 04
2
1
1
2
10
.03
Checking/adjusting the air pressure
●
Before operating the machine, always
check the air pressure on gauge
1
.
●
Gauge
1
must show a pressure of
6 bar
.
●
If necessary adjust to this reading.
●
To do so, pull knob
2
upwards and turn it
so that the gauge shows a pressure of
6
bar
.