Adjustment
70
Move the needle bar 1 to t.d.c.
Adjust the needle bar
1
(screws
2
) according to the
rule
.
1
2
Fig. 13 - 03
13
.06.03
Pre-calibrating needle height
Rule
3811
-
3/55
3811
-
15/65
-
16/65
3
4
1
5
3
4
1
5
X
When the needle bar is at t.d.c., Needle bar (adjustment hole
1
), the clear-
ance
X
between the needle plate and the needle point should be
11 mm.
When the needle bar is at t.d.c., Needle bar (adjustment hole
1
), the clear-
ance
X
between the needle plate and the needle point should be
14 mm.