Set-up and Initial Start-up
26
8
.02
Initial commissioning
Before initial commissioning,
remove the protective fi lm from
the sight glass
1.
Clean the machine thoroughly and then
check the oil level, see
Chapter 12
Maintenance and Care.
Inspect the machine, particularly the
electric cable, for any damage.
Arrange for technical staff to check
whether the machine's motor may be
operated at the existing mains voltage
and whether it is connected properly.
Never operate the machine if there are any differences.
The machine must only be connected to a grounded socket!
With the machine running, the handwheel must turn towards the operator, otherwise ar-
range for technical staff to adjust the motor, see
Chapter 13.07 Parameter settings.
For machines with pneumatic devices, the machine must be connected to the
compressed air system. The manometer should show a pressure of 6 bar. Or set this
value (see
Chapter 12.04 Checking/setting the air pressure
).
8
.03
Switching the machine on/off
Switch machine on and off (see
Chapter 7.01 Main switch
).
Perform test run
Fig. 8 - 09
1