Adjustment
12 - 32
3
306
Reverse position
0 – 127
103
307
Placement stitch position
0 – 127
7
308
Position thread tension release
0 – 127
101
4
401
Delay time lifting roller presser
[s]
0.01 – 1.50
0.02
402
Start delay after lowering roller presser
[s]
0.01 – 1.50
0.15
403
Set lift roller presser
[s]
0.01 – 0.20
0.03
404
Tact thread cutting solenoid (%)
10 - 50
35
405
Time for cleaning thread monitor
[s]
0.01 - 1.50
0,25
5
501
Maximum speed
100 – 3500
3500
502
Speed start backtack
100 – 1500
700
503
Speed end backtack
100 – 1500
700
504
Speed soft start
100 – 3500
1500
505
Soft start stitches
0 – 15
0
6
601
Move stepping motor roller presser
and feed wheel
602
Display inputs
0123456789ABCDEF
0: not assigned (E16)
1: not assigned (E15)
2: Coding intermittent (E14)
3: not assigned (E13)
4: not assigned (E12)
5: not assigned (E11)
6: not assigned (E10)
7: not assigned (E9)
8: not assigned (E8)
9: Bobbin thread error (E7)
A: Knee switch (E6)
B: not assigned (E5)
C: not assigned (E4)
D: not assigned (E3)
E: not assigned (E2)
F: not assigned (E1)
603
Basic position of the machine drive unit
11 ± 2
( see Chap. 8.02.04 )
604
Carry out cold start ( see Chap. 12.09 )
605
Stitch formation check by turning the
balance wheel
Group
Parameter
Description
Setting
Set
range
value
Summary of Contents for 3734-12
Page 83: ...14 2 91 191 492 95 Part 1 Version 25 08 05 General plan circuit diagrams...
Page 84: ...14 3 General plan circuit diagrams Version 25 08 05 91 191 442 95 Part 2...
Page 85: ...14 4 91 191 492 95 Part 3 Version 25 08 05 General plan circuit diagrams...
Page 86: ...14 5 General plan circuit diagrams Version 25 08 05 91 191 442 95 Part 4...
Page 87: ...Notice...