Adjustment
13 - 25
13
.07.05
Engaging solenoid
Requirement
With the needle bar at 1.8 past BDC (hole 4), there should be a distance of
0.2
to
0.3 mm
between engaging lever
1
and latch
2
when the engaging solenoid is actuated.
●
Position the needle bar at 1.8 past BDC.
●
Actuate engaging lever
1
by hand until latch
2
engages.
●
Press the magneto inductor into solenoid housing
2
as far as it will go and move solenoid
housing
3
(screw
4
) according to the
requirement
.
Fig. 13 - 24
24V = 4% ED
4
3
2
1
0.2 -
0.3 mm
2