Input
68
Group
Parameter
Description
Setting range
Set value
2
206
Open thread tension on stop and roller presser lift
ON - OFF
OFF
207
Open thread tension after trimming
ON - OFF
OFF
3
301
Take-up lever at t.d.c. position
1591
0 - 127
125
1593
0 - 127
2
302
Position of needle at bottom position
1591
0 - 127
17
1593
0 - 127
20
303
Thread trimmer magnet position on
1591
0 - 127
17
1593
0 - 127
20
304
Thread trimmer magnet position timing
1591
0 - 127
100
1593
0 - 127
103
305
Thread trimmer magnet position off
1591
0 - 127
120
1593
0 - 127
123
306
Reverse rotation position
1591
0 - 127
100
1593
0 - 127
103
307
Placed stitch position
0 - 127
7
308
Thread tension ventilation position
1591
0 - 127
98
1593
0 - 127
101
4
401
Holdoff time roller presser lift [s]
0.01 - 1.5
0.02
402
Start delay after lower roller presser [s]
0.01 - 1.5
0.15
403
Set roller presser lift [s]
0.01 - 0.2
0.03
404
Thread trimmer magnet timing [%]
10 - 50
35
405
Time to clean the thread monitor [s]
0.01 - 1.5
0.25
5
501
Maximum speed
100 - 3500
3500
502
Start backtack speed
100 - 1500
700
Summary of Contents for 1591
Page 77: ...77 13 Table Top 13 01 Tilt base Tilt base 2x rawlplugs ...
Page 81: ...Notes ...