Sewing
20
5
.01.01
Entering the seam start and seam end in manual sewing mode
After the appropriate function has been selected, the menu for entering the value for con-
densed stitches or for backtacks appears.
PFAFF 487, 489
PFAFF 5487
PFAFF 487
●
,
489
Switch on the single start backtack function and call up the menu for entering the values.
(
1
–
9
stitches can be entered).
or
Switch on the double start backtack function and call up the menu for entering the values.
●
(
1
–
9
stitches can be entered).
PFAFF 5487
●
Switch on the condensed stitches function and call up the menu for entering the values.
(
1
–
30
stitches can be entered).
In each case change the number of stitches for the condensed stitches or the number of
●
backtack stitches with the appropriate arrow keys.
Change the value for the maximum speed during the condensed stitches or backtacking
●
operation (
100
–
1500
spm can be entered).
Choose whether the condensed stitches or the backtacking operation at the beginning of
●
the seam should be carried out at a fi xed speed (normal symbol) or at a pedal-controlled
speed (inverse symbol).
Conclude the input.
●
In the manual sewing mode, the functions for the seam end are entered in the same way
●
as those for the seam start.