
Installation and commissioning
12
3
.02.02
With control unit P323 MS
Switch on the machine.
●
Call up the input mode.
●
Call up the service function.
●
By turning the balance wheel in the sewing direction, ascertain the number of incre-
●
ments per turn (this maximum value appears under "POS" in the display before the rea-
ding jumps back to "
0
".
Call up the input mode.
●
Call up parameter "
●
721
".
721
127
Enter the calculated max. value.
●
Conclude the input.
●
Switch off the machine.
●