12
compressor can be judged from illuminating and putting out of the indicator. On control
panel, when compressor is on working, the sign ‘run’ on the top left corner of blue
screen will be illuminated.
When temp inside the cabinet is lower than the set temp, thermal compensation system of the wine
cooler will start working, indicator on bottom right of the control panel will light up.
After set temp is locked, it will flash for 3 seconds, indicating the actual temp inside the cabinet.
Afterwards, temp inside the cabinet will reach the set temp, fluctuating around±2.5
℃
of set temp which is
regarded as normal.
The button power controls running and stopping of the whole system of wine cooler, but every starting
and stopping, the system won’t start until 5 seconds after delay protection.
Self-detection:
When power is on for the whole cabinet by touching button ‘power’, mode of self-detection will start.
In the process of detection, the figure on digital tube will be circularly lighted up, all the electrical ports will
be put into power from which we can judge whether the whole system is running normally. Upon
completion of detection after 10 seconds, normal mode of working will automatically start.
Alarm system:
When faults of cooling systems for all the models of wine coolers occur, temp inside the cabinet runs
higher than ≥30
℃(
86
℉)
for more than 2 hours, alarm system will work, the cooling system will be
automatically shut off with the buzzer buzzing intermittently.
Embedded diagram:
Please follow the diagram as shown below if user wants to insert the wine cabinet into any solid
structure.
◆
For wine cooler with recessed base