Pevex Stoves - Brightwell 400P
– Installation & Operating Manual
AIR MANAGEMENT DAMPERS LEFT OPEN
Operation with the air control or appliance dampers open can cause excess smoke. The appliance must not
be operated with air controls, appliance dampers or door left open except as directed in the instructions.
OPERATION WITH DOOR LEFT OPEN
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance
door left open except as directed in the instructions.
REQUIREMENTS FOR THIS BRIGHTWELL STOVE WHEN BEING USED IN A SMOKE CONTROLLED
AREA
The Brightwell Multifuel Stove has been recommended as suitable for use in smoke control areas when burning
wood logs.The Brightwell Multifuel Stove must be fitted with a permanent stop to prevent closure of the
secondary/tertiary control rod beyond the 11.5mm open postion.
The DEFRA limiter supplied with the stove
must be fitted to meet the requirements before use of the stove
FITTING THE DEFRA LIMITING FIXTURE TO THE STOVE TO COMPLY WITH THE CLEAN AIR ACT AND
DEFRA
Drawing not to scale
Showing
Optional
External Air
Kit
Fitted
DEFRA - CLEAN AIR
LIMITING SCREW
FIXTURE
M6 x 12mm Socket Head
Cap Screw & Nut
– FIG 1
Secondary Air
Control Lever for
the Secondary &
Tertiary Air Inlet
Control Damper
Primary
Air
Control
Lever
AIR MANAGEMENT
CONTROL VALVE
Fitted to the
underneath of the
stove
INSTRUCTIONS ON HOW TO FIT THE DEFRA LIMITING SCREW FIXTURE
1 If not ready fitted to your stove please fit a M6 x 12 Capscrew & Nut before the stove is installed
other you will not be able to fit it once the stove is installed
.
2 Pull out the Secondary Air Control lever and it will expose the hole in the paddle, Fit the M6 x 12
Capscrew & Nut as shown in Fig 1 above
NOW THIS IS FITTED THIS STOVE CAN BE USED IN A CLEAN AIR CONTROLLED AREA. BY
FITTING THIS LIMITER THIS WILL PREVENT THE SECONDARY SLIDER FROM FULLY CLOSING
AND REDUCE THE SMOKE OUTPUT OF THE STOVE
Non-
Combustible
Hearth