Page
17
of 28
Brightwell 400P
–
July 2022 v1
Pevex Stoves - Brightwell 400P
– Installation & Operating Manual
CLEARANCES TO NON COMBUSTIBLES
If you are fitting the stove into a brick buil
t fireplace and it’s deemed as
Non-combustible
you would still fit the
Non-combustible hearth
but you could then reduce the distance around the back and the sides of the stove to
the non-combustible brick wall, we would recommend 100 mm this allows you access around the stove for
servicing
COMMISSIONING AND HANDOVER
On completion of the installation allow a suitable
period of time for any fire cement and mortar to dry
out, when a small fire may be lit and checked to
ensure the smoke and fumes are taken from the
stove up the chimney and emitted safely to the
atmosphere.
Do not run at full output for at least
24 hours.
Ensure that the operating instructions for the stove
are left with the customer. Ensure to advise the
customer on the correct use of the appliance with
the fuels likely to be used on the stove and warn
them to use only the recommended fuels for the
stove. Advise the user what to do should smoke or
fumes be emitted from the stove.
OPERATION
Check that all 2 x Air Control levers/dampers and
Door catch are operating correctly and ensure that
all flue connections are thoroughly sealed.
AIR CONTROLS
The stove has two independent Air Controls:
1.
The Primary Air Control Lever
which controls the
Primary Air (See Fig 10). Easily PULL out to open
&
push in to close
.
.
WARNING:
DO NOT OBSTRUCT PRIMARY, SECONDARY OR TERIARY AIR SUPPLY TO THE
STOVE, THIS IS FED FROM THE MIDDLE REAR UNDERNEATH OF THE STOVE
Note:
Dimensions stated are in millimetres (mm) unless otherwise stated and may be subject to a /- variation.
2.
The Secondary Air Control Lever
which
controls the Secondary Air (air wash down the
glass in the door) and the Tertiary Air for the air in the back
of the stove (See Fig 10). Easily Pull out to open
& push in to close
Note:
The controls may become HOT when the
stove is in operation, use the heatproof glove
provided to adjust the controls when the stove
is hot
The customer should be warned to use a
fireguard to BS 8432: 2010 in the presence
of children, aged and/or infirm persons.
Fig 10
Tertiary Air holes expel
air which then burns off
the unburnt gases from
the firebox for maximum
efficiency &
performance
Control
Lever for the
Secondary
and Tertiary
Air Control
Control
Lever for the
Primary Air
Control
FIG AA
Maximum Load
line 75mm below
the Tertiary Air
Holes
Secondary Air,
this clean air
wash flows
down the inside
of the door glass
to keep the glass
clean
MAXIMUM LOADING OF FUEL ON
THE FUEL BED
– SEE FIG AA