9
5 s
5 minutes
Fig. 3
Fig. 4
RESET
Fig. 5
2.2 - NEW DEVICE
When turned on, the receiver has only the
lit.
ON LED
N.B.:
lower
There may be a weak lighted signal on the
of the
, due to the presence of radio interference.
LED
VMETER
2.3 - TEMPORARILY FORCING THE STATE OF THE CONTROL OUTPUT
(for example, to test the system)
B) TRANSMITTER COUPLED AND HEAT REGULATION ACTIVE
The above-indicated operations can also be performed, using the same methods, during normal heat regulation operation; in this case,
the temporary forced control will cause the transmitter to be excluded and the reversal of the command status: if active, it will be
deactivated and vice versa. During the forced state, the “
”
is not functional.
key
Cancelling the temporary forcing of the control
!
Briefly press the
; when released the temporary forced control is
“
”
Reset key
cancelled (fig.5).
N.B.:
Reset
Before performing this operation, consult chapter 2.9
“
”
A) TRANSMITTER NOT YET COUPLED OR NOT ACTIVE
!
Hold down the “
”
until there is a brief audible signal, then release it: the control is activated and the corresponding
is
key
LED
steady on (fig.3).
The control will remain activated for 5 minutes, at the end of which, an audible signal will continue for
to alert the operator of
5 seconds
its imminent deactivation (fig.4): if you wish to keep it active, press the “
”
again while the audible signal is sounding;
key
otherwise, when the signal ceases, the control will be deactivated.