background image

19

O

2

asis User Guide

Reprocessing and Disinfection Between Patients

The O2asis Humidifier Base must always be cleaned and disinfected between 
patients. The entire Water Well consumable cartridge, including its blue 

heated 

line

, is disposable and no disinfection is required. Follow these steps to ensure 

a clean and disinfected device:

1

Unplug the O

2

asis Humidifier Base from the power supply.

2

Remove and discard the Cannula (  single-patient use).

3

Remove and discard the Water Well consumable cartridge (  single-
patient use).

4

Examine for visible soil. If visible soil is present, use a wetted soft nylon 
bristle brush or Super Sani-Cloth® to remove all visible soil, paying close 
attention to seams and crevices in the device.

5

Wet all surfaces of the base unit with another Super Sani-Cloth®. Keep 
the surface wet for at least two minutes. Use additional Super Sani-
Cloth® if needed.

6

Allow the device to air dry completely.

7

If Power Supply is exposed to the patient, disconnect from the O2asis 
device and wall. Repeat steps 4 through 6, and let thoroughly dry.

 Warning:

 

Do not

 use organic solvents or abrasive cleaners. These types of 

cleaners may create toxic gasses when heated and may damage the device.

 Warning:

 Water fill pump is intended for   single patient use only. The 

Water Fill Pump should not be used between multiple patients. It cannot be 
reprocessed. If the pump may have been contaminated, replace or provide 
patient with new pump.

The Super Sani-Cloth® Germicidal Disposable Wipe is a premoistened nonwo-
ven durable wipe containing a quaternary ammonium chloride/alcohol-based 
solution. It is recommended for use in hospitals and other critical care areas 
where the control of the hazards of cross-contamination between treated 
surfaces is required, and it is designed to be compatible with hard nonporous 
surfaces and equipment made of plastic, Formica® laminate, glass and more. 
Some organisms are removed from the surface by thoroughly wiping the sur-
face with the wipe. Most remaining organisms are killed within two (2) minutes 
by exposure to the liquid in the wipe.
The Super Sani-Cloth Wipe is registered with the Environmental Protection 
Agency (EPA) under (EPA #9480-4). In accordance with 21 CFR 880.6890, 
the Super Sani-Cloth Wipe is regulated by the FDA as a Class I, 510(k) Exempt, 
General Purpose Disinfectant under Product Code (LRJ).

PP-19-1 REV. 15

Summary of Contents for O2asis

Page 1: ...Personal Humidifier USER GUIDE PP 19 1 REV 15...

Page 2: ...und to be defective within the stated warranty period Should the O2asis base unit or the replacement water well fail prematurely the replacement base unit is warranted for the remainder of the origina...

Page 3: ...djusting the Heat Level 13 Pediatric Patients 13 Use Without Electrical Power 14 Replacing the Water Well Consumable Cartridge 15 Checking for an empty Water Well 17 Cleaning and Disinfection 18 Regul...

Page 4: ...the power cord in a way that will avoid anyone tripping or anything otherwise interfering with it Do not position the device in a way that would make it difficult to access the power supply connection...

Page 5: ...er Do not attempt to use with or connect to other medical equipment This device is not intended for connection to a medical pipeline This device is not intended for use with patients whose upper airwa...

Page 6: ...ryloni trile which is known in the state of California to cause cancer For more information go to www p65warnings ca gov INCLUDED WITH THE SYSTEM The O2asis Humidifier comes with the following parts N...

Page 7: ...wer Cord Connector The connector that accepts the male connector at the end of the power cord 6 Heated Line The heated tube attached to the Water Well cartridge that heats the oxygen to prevent water...

Page 8: ...ns Heated Line Power Levels Water Heater Temperature Levels Water Heater power turned off when Heated Line is not detected LED Indicator Lights 3 LED Indicator Lights low medium high User Interfaces T...

Page 9: ...e For additional reservoir durations please refer to the Performance section of this manual Note The device will detect when the Water Well is empty and will shut down The three LED lights will flash...

Page 10: ...o prevent over filling the pump should not be used while the Water Well is disconnected from the Base Unit Confirm that the electrical port is dry and reattach the device to an electrical outlet If th...

Page 11: ...ment Note Make sure that the Water Well consumable cartridge is securely latched to the base unit before plugging in the power cord Note The O2asis Humidifier device will continue to humidify the airf...

Page 12: ...steps Warning Use only the cannula included with the device Use of other cannulas can degrade the performance of the device 1 Remove the cannula from its plastic bag 2 Connect the tube end to the conn...

Page 13: ...ed oxygen flow as shown in the table below 2 Above 2lpm of oxygen flow begin your oxygen therapy on the first level of heat When the device receives power the left most LED light will illuminate signi...

Page 14: ...in Adjusting the Heat Level sec tion of this document Condensation Regularly check for visual condensation in the cannula If excessive amounts of condensation are present reduce the heat setting to t...

Page 15: ...age device To replace the Water Well consumable cartridge complete the following steps 1 Unplug the power adapter cord from the latch side of the device 2 Unplug the oxygen source line from the oxygen...

Page 16: ...ging 8 Insert the non port side of the cartridge into the button side of the base and push in until the cartridge sits flush with the base 9 Swing the base latch up and snap it onto the cartridge to l...

Page 17: ...d can become contaminated with bodily fluids If visible contamination is present or performance degradation is suspected dispose of and replace the Water Well consumable cartridge Warning Do not touch...

Page 18: ...oap Wipe all exterior surfaces If visible soil is present use a wetted soft nylon bris tle brush to remove visible soil paying close attention to seams and crevices in the device Wipe again with dish...

Page 19: ...ganic solvents or abrasive cleaners These types of cleaners may create toxic gasses when heated and may damage the device Warning Water fill pump is intended for single patient use only The Water Fill...

Page 20: ...hysical Dimensions 187 x 102 x 30mm 7 4 x 4 0 x 1 2 in Not including 1118mm 44 in long heated line Weight 0 7 lbs 65lbs 295 g empty 10 95 lbs 430 g full Distilled water reservoir approx capacity 135 m...

Page 21: ...ion This device is an US FDA cleared Class II medical device This device is considered an IEC Class II continuous operation ordinary equipment device The heated line with cannula is considered an IEC...

Page 22: ...w Rate lpm liters per minute Leakages ml milliliters Oxygen Supply Flow Rate Range 0 5 lpm to 6 lpm Maximum Oxygen supply flow rate 6 lpm ESTIMATED HUMIDIFICATION OUTPUT Dry Oxygen Flow Rate Heat Sett...

Page 23: ...Warning Portable RF communications equipment including peripherals such as antenna cables and external antennas should be used no closer than 30 cm 12 inches to any part of the O2asis Humidifier Syst...

Page 24: ...domestic purposes Harmonic emissions IEC 61000 3 2 Class A Voltage fluctuations flicker emissions IEC 61000 3 3 Complies Immunity Electromagnetic Immunity The O2asis Humidifier is intended for use in...

Page 25: ...io bands 10 V m The O2asis Humidifier is suitable for the electromagnetic environment of typical homes commercial or hospital settings DISPOSAL Base Unit This device should be disposed of separately f...

Page 26: ...snug If the device still does not provide the proper air flow please contact the care provider licensed distributor or O2asis to return the device Problem Possible Cause Action to Take The temperatur...

Page 27: ...ng comfort anymore please purchase a new Water Well to restore full comfort Problem Possible Cause Action to Take The device does not seem to be operating correctly You accidentally spilled water onto...

Page 28: ...1001 New Hampshire Ave Lakewood NJ 08701 USA Toll Free 1 800 337 3762 www o2asishumidifier com...

Reviews: