32
SEBU8605-01
Operation Section
Lifting and Storage
i04195469
Product Lifting
(Clean Emission Module)
g02385036
Illustration 32
Ensure that the correct clothing is worn, refer to
this Operation and Maintenance Manual, “General
Hazard Information”.
The weight of the clean emission module (CEM)
when laden is approximately 50 kg (110 lb). Two
suitable double looped slings are required in order to
lift the CEM. Also a suitable hoist will be required in
order to remove and install the assembly.
The slings must be attached to the CEM in the
positions as shown in illustration 32.
Ensure that the slings only contact the body of the
CEM. A test lift may be required in order to achieve
the correct balance of the assembly.
Some applications may require a frame or jig in order
to lift the CEM. A frame or jig must only be connected
to the cradle of the CEM. Refer to the OEM for more
information.
i04084189
Product Storage
(Engine and Aftertreatment)
Perkins are not responsible for damage which may
occur when an engine is in storage after a period in
service.
Your Perkins dealer or your Perkins distributor can
assist in preparing the engine for extended storage
periods.
Condition for Storage
The engine must be stored in a water proof building.
The building must be kept at a constant temperature.
Engines that are
fi
lled with Perkins ELC will have
coolant protection to an ambient temperature of
−
36° C (
−
32.8° F). The engine must not be subjected
to extreme variations in temperature and humidity.
Storage Period
An engine can be stored for up to 6 months provided
all the recommendation are adhered to.
Storage Procedure
Keep a record of the procedure that has been
completed on the engine.
Note:
Do not store an engine that has biodiesel in
the fuel system.
1.
Ensure that the engine is clean and dry.
a.
If the engine has been operated using biodiesel,
the system must be drained and new
fi
lters
installed. The fuel tank will require
fl
ushing.
b.
Fill the fuel system with an ultra low sulfur fuel.
For more information on acceptable fuels refer
to this Operation and Maintenance Manual,
“Fluid recommendations”. Operate the engine
for 15 minutes in order to remove all biodiesel
from the system.
2.
Drain any water from the primary
fi
lter water
separator. Ensure that the fuel tank is full.
3.
The engine oil will not need to be drained in
order to store the engine. Provided the correct
speci
fi
cation of engine oil is used the engine
can be stored for up to 6 months. For the
correct speci
fi
cation of engine oil refer to this
Operation and Maintenance Manual, “Fluid
recommendations”.