32
Application
Hydraulic Head Spindle Device VST
Translation of the Original Instructions for Use
Lowering
Danger
Personal injury and material damage!
– Lower only if the concrete has
hardened enough and the person
in charge has given instructions to
do so!
– During operations, keep hands and
feet away from the cylinder and
Head Spindle VST 100 in order to
prevent injuries!
– With a multiple number of spindles,
ensure that all spindles are lowered
uniformly!
– Do not exceed the max. operating
pressure 680 bar (700 kN)!
– Project-specific statics, a pre-ten-
sioning or lowering plan is required!
Lower the Head Spindle VST 100 in
maximum 10 mm increments.
Operating pressure conversion in kN
1 bar
= 1.026 kN
1 psi
= 7.074 kN