12.6 Settable Parameters
For more information on Juno host commands refer to the
Juno Velocity & Torque Control IC Programming Reference
.
Parameter
Host Command
Mnemonic
Range & Description
Signal sense mask
SetSignalSense
Specified value is a 16-bit mask with each '1' bit value indi-
cating invert, and each '0' bit value indicating don't invert
Fault out mask
SetFaultOutMask
Specified value is a 16-bit mask with each '1' bit value indi-
cating that the corresponding bit in the Event Status regis-
ter, if active, will drive the
FaultOut
signal active.
Event action process-
ing
SetEventAction
Two parameter command. The first is a fixed value that
specifies the event condition for which an action is being
defined, the second is a fixed value defining the action.
Juno defines 10 separate event conditions and therefore
this command could be called up to 10 times, one for
each condition
Event recovery
method
SetDriveFaultParameter
Two parameter command. The first must be 2, the sec-
ond is a fixed code value specifying either Enable-based
(automatic) event recovery or commanded event recov-
ery.
Host interrupt mask
SetInterruptMask
Specified value is a 16-bit mask with each '1' bit value indi-
cating that the corresponding bit in the Event Status regis-
ter, if active, will trigger a host interrupt and drive the
HostInterrupt