Motion Monitoring & Control
72
Juno Step Motor Control IC User Guide
12
12.1.2 Activity Status Register
Activity Status register bits are not latched, they are continuously set and reset to indicate the status of the
corresponding conditions.
The Activity Status register is defined in the following table:
12.1.3 Drive Status Register
The specific status bits provided by the Drive Status register are defined in the following table. Like the Event Activity
Status Register these bits are not latched.
Bit
Name
Description
0
Reserved
May contain 0 or 1.
1
At maximum velocity
Set 1 when the commanded velocity is equal to the maximum velocity specified by the
host. Cleared 0 if it is not. This bit only functions in conjunction with the profile
generator and is not set if the loop command source is set to anything other than profile
generator.
2-8
Reserved
May contain 0 or 1.
9
Position capture
Set 1 when a new position value is available to read from the Index capture hardware.
Cleared 0 when a new value has not yet been captured. A serial host command retrieves
the captured position value and clears this bit, thus allowing additional captures to occur.
While this bit is set, no new values will be captured.
10
In-motion indicator
Set 1 when the profile generator commanded position is changing. Cleared 0 when the
commanded position is not changing.
11-15
Reserved
May contain 0 or 1.
Bit
Name
Description
0
Calibration completed
Set 1 when an analog input calibration procedure is completed. Cleared if not
completed.
1
In foldback
Set 1 when in foldback, cleared 0 if not in foldback.
2
Overtemperature
Set 1 when the axis is currently in an overtemperature condition. Cleared 0 if the
axis is currently not in an overtemperature condition.
3
Reserved
May contain 0 or 1.
4
In holding
Set 1 when the axis is in a holding current condition, cleared 0 if not.
5
Overvoltage
Set 1 when the axis is currently in an overvoltage condition. Cleared 0 if the axis is
currently not in an overvoltage condition.
6
Undervoltage
Set 1 when the axis is currently in an undervoltage condition. Cleared 0 if the axis
is currently not in an undervoltage condition.
7-11
Reserved
May contain 0 or 1.
12
Output Clipped
Set 1 when the amplifier current command can not be met because of output
clipping.
13
Reserved
May contain 0 or 1.
14
Initializing
Set 1 when Juno is initializing from NVRAM commands. Set 0 when initializing is
complete.
15
Reserved
May contain 0 or 1.