background image

13

NOTE

A highly recommended troubleshoot for any issue in general consists of turning off unit and unplugging for 5 

minutes. It is also recommended to try another wall outlet. For further assistance, contact Consumer Services at 

844-472-2473.

TROUBLESHOOTING

BEFORE CALLING FOR SERVICE, PLEASE REVIEW THE CHART BELOW

ISSUE

POSSIBLE CAUSES

AIR CONDITIONER NOT

COOLING ROOM, OR NOT BLOWING 

COLD AIR

• Be sure unit is not too large or too small for the area of the room.

• Verify that all doors, windows, curtains and any other openings are closed off. 

Verify nothing is obstructing the front grille of unit, such as curtains, etc.

• Allow enough time for room to cool, especially if outside temp is very high.

• Check that the filter is not dirty and louvers are open all the way and blowing in the 

desired direction.

• Check that unit is set to COOL mode and that temperature is down enough (but 

not too low).

• If unit is near a heat source, such as a stove, etc., then relocate unit.

• If air coming from unit is cool to the touch, then unit is working properly; please 

double check the first three bullet points above.

• If using Follow Me remote feature, move remote away from unit.

• Temperature sensor behind air filter touching cold coil. These two elements should 

not be touching. Carefully straighten tube away from coil.

• Unplug unit for at least 5 minutes. Follow Reset instructions on plug.

AIR CONDITIONER COOLING 

BUT ROOM IS TOO WARM - ICE 

FORMING ON COOLING COIL 

BEHIND DECORATIVE FRONT

• Outdoor temperature is below 64ºF (18ºC). To defrost the coil, set to FAN  

only mode.

• Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, 

set to FAN only mode.

• Thermostat is set too cold for night-time cooling. To defrost the coil, set to FAN  

only mode. Then, set temperature to a higher setting.

AIR CONDITIONER CYCLING ON  

AND OFF TOO FREQUENTLY OR  

NOT ENOUGH

• Be sure unit is not too large or too small for the area of the room.

• Remove grille and make sure the temperature sensor is not too close to the coils. 

These two elements should not be touching. Carefully straighten tube away  

from coil.

• Make sure nothing is blocking the grille or side vents.

• Make sure there is no dirt or debris inside the unit or on the filter.

UNIT WILL NOT TURN ON

• Reset circuit breaker. Make sure there are not too many items (i.e. lamps, TV’s, 

etc.) working off the same breaker.

• Check plug connection.

• If plug is operating on an on/off switch, be sure that the switch is ‘on’.

• Try plugging unit into another outlet.

• Unplug unit for at least 5 minutes. Follow Reset instructions on plug.

UNIT BLOWS FUSES OR POPS 

CIRCUIT BREAKER

• Make sure there are enough available amps on the circuit for the air conditioner.

• Large units which run on a 230v will require a dedicated 20 or 30 amp circuit.

AIR CONDITIONER IS  

MAKING NOISES

• Check to be sure the unit is free from debris such as leaves, sticks, etc. Verify 

nothing is obstructing the unit.

• Check the fan blade for cracks or chips.

• Make sure the unit is properly and securely mounted inside the window or wall.

• Clean the air filter.

WATER PUDDLES INSIDE UNIT OR IS 

COMING INTO ROOM

• Adjust the slope of the unit so that it drains downward toward the exterior of the 

home. (See Installation Instructions.)

• Make sure that there is no debris blocking the drainage area of the unit.

WATER DRIPPING OUTSIDE

• Unit is removing a large quantity of moisture from a humid room. This is normal 

during excessively humid days.

REMOTE SENSING / FOLLOW ME 

DEACTIVATING PREMATURELY

• Remote control not located within range. Place remote control within 20 ft and 

180º radius of the front of the unit.

• Remote control signal obstructed. Remove obstruction.

Summary of Contents for 5PAC10000

Page 1: ...WINDOW AIR CONDITIONER FOR MODEL 5PAC10000 5PAC12000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...or installation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be supervised to ensure that they do not play wi...

Page 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Page 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire Do not place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Page 6: ...sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this un...

Page 7: ...is designed to install in standard double hung windows with opening widths of 23 to 36 inches 584 mm to 914 mm NOTE H vertical opening See table below TABLE 1 Model 5000 8000 Btu h 10000 12000 Btu h...

Page 8: ...nergy Star rated units only TOP RAIL HARDWARE 3 8 Screws 4 pcs Top Rail 1 pc Insulation Panels 2 pcs C Align the hole in the top rail with those in the top of the unit as shown in Fig B D Secure the t...

Page 9: ...ly H Fig 5 above tilted about 3 to 4 downward to the outside If after proper installation condensation does not drain from the overflow drain hole during normal use adjust slope B Extend the accordion...

Page 10: ...se instructions STEP 6 1 After the unit is installed in the window measure the inner width of one of the accordion panels as shown in Fig 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 STEP...

Page 11: ...rain holes or slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out REMOVING AC FROM WINDOW Turn AC off and disconnect power cord Remove sash seal f...

Page 12: ...ollow the symbol for the functions you desire BEFORE operating the unit This unit can be controlled by the unit control or the remote control TIMER ECO MODE FILTER On Off Auto Cool Dry Fan Follow me A...

Page 13: ...lluminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver function under COOL DRY and AUTO only AUTO COOLING and AUTO FAN modes TO OPERATE AUTO FEATURE W...

Page 14: ...t throughout the room as needed Pivot horizontal louvers until the desired vertical up down direction is obtained Move the levers from side to side until the desired horizontal left right direction is...

Page 15: ...lacing As an alternative to washing the filter vacuum the filter clean NOTE Never use hot water over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET...

Page 16: ...he coil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the roo...

Page 17: ......

Page 18: ......

Page 19: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Page 20: ...Belt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User5PAC10...

Reviews: