IMPORTANT SAFETY INSTRUCTIONS

 NOTE:

The power supply cord with this air 

conditioner contains a current detection 

device designed to reduce the risk 

of fire. Please refer to the section 

“Operation of Current Device” (below) 

for details. In the event that the power 

supply cord is damaged, it cannot be 

repaired. It must be replaced by an 

authorized repair technician with a cord 

from the Product Manufacturer.

WARNING

Avoid fire hazards or electric shock. 

DO 

NOT

 use an extension cord or an adapter 

plug. 

DO NOT

 remove any prong from the 

power cord.

OPERATION OF  

CURRENT DEVICE:

The power supply cord contains a 

current device that senses damage 

to the power cord. To test your power 

supply cord, do the following: 

1.  Plug in the air conditioner.

2.  The power supply cord will have 

TWO buttons on the plug head. Press 

the TEST button. You will notice a 

click as the RESET button pops out.

3.  Press the RESET button. Again, 

you will notice a click as the  

button engages.

4.  The power supply cord is now 

supplying electricity to the unit. (On 

some products this is also indicated 

by a light on the plug head.)

WARNING

FOR YOUR SAFETY: Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other appliances.

WARNING - PREVENT ACCIDENTS

To reduce the risk of fire, electrical shock, or injury to persons when using 

your air conditioner, follow basic precautions, including the following: 

●  Be sure the electrical service is adequate for the model you have 

chosen. This information can be found on the serial plate, which is 

located on the side of the cabinet and behind the grille.

●  If the air conditioner is to be installed in a window, you will probably 

want to clean both sides of the glass first. If the window is a triple-

track type with a screen panel included, remove the screen completely 

before installation.

●  Be sure the air conditioner has been securely and correctly installed 

according to the installation instructions in this manual.

●  Save this manual for possible future use in removing or installing this unit.

●  When handling the air conditioner, be careful to avoid cuts from sharp 

metal fins on front and rear coils.

WARNING - ELECTRICAL INFORMATION

The complete electrical rating of your new room air conditioner is  

stated on the serial plate. Refer to the rating when checking the  

electrical requirements.

●  Be sure the air conditioner is properly grounded. To minimize shock 

and fire hazards, proper grounding is important. The power cord is 

equipped with a three-prong grounding plug for protection against 

shock hazards. 

●  Your air conditioner must be used in a properly grounded wall 

receptacle. If the wall receptacle you intend to use is not adequately 

grounded or protected by a time delay fuse or circuit breaker, have a 

qualified electrician install the proper receptacle.

●  Ensure the receptacle is accessible after the unit installation.

●  Do not run air conditioner without side protective cover in place. This 

could result in mechanical damage within the air conditioner.

●  Do not use an extension cord or an adapter plug.

 NOTE:

Do not use the plug to turn the unit on or off.

●  Always make sure the RESET button is pushed in for correct operation.

●  The power supply must be replaced if it fails reset when either the TEST 

button is pushed or it cannot be reset.

●  If power supply cord is damaged, it cannot be repaired. Please call 

Consumer Services at 844-472-2473 to assist with replacement.

NOTE:

 This air conditioner is designed to be operated under the

following conditions:

Cooling 

Operation

Outdoor Temp:

64 – 109°F/18 – 43°C

(64 – 125°F/18 – 52°C for special tropical models)

Indoor Temp:

62 – 90°F/17 – 32°C

Performance may be reduced outside of these operating temperatures.

Grounding Type

Wall Receptacle

Do not, under any 

circumstances, cut, 

remove, or bypass the 

ground prong.

Power supply cord  

with 3-prong grounding 

plug and current 

detection device

Summary of Contents for 5PAC10000

Page 1: ...WINDOW AIR CONDITIONER FOR MODEL 5PAC10000 5PAC12000 Before using your air conditioner please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Page 2: ...___________________________ Purchase Date _____________________________________ Store Purchased ______________________________________ Installation Date ____________________________________ Installati...

Page 3: ...or installation of this unit if necessary The air conditioner is not intended for use by young children without adult supervision Young children should be supervised to ensure that they do not play wi...

Page 4: ...the unit Failure to do so may cause fire and electric shock DO NOT use the socket if it is loose or damaged Doing so may cause fire and electric shock DO NOT open the unit during operation Doing so m...

Page 5: ...d of time unplug or turn OFF main power switch Leaving power on may cause unit failure or fire Do not place obstacles around air inlets or inside of air outlet Obstacles may cause appliance failure or...

Page 6: ...sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual Save this manual for possible future use in removing or installing this un...

Page 7: ...is designed to install in standard double hung windows with opening widths of 23 to 36 inches 584 mm to 914 mm NOTE H vertical opening See table below TABLE 1 Model 5000 8000 Btu h 10000 12000 Btu h...

Page 8: ...nergy Star rated units only TOP RAIL HARDWARE 3 8 Screws 4 pcs Top Rail 1 pc Insulation Panels 2 pcs C Align the hole in the top rail with those in the top of the unit as shown in Fig B D Secure the t...

Page 9: ...ly H Fig 5 above tilted about 3 to 4 downward to the outside If after proper installation condensation does not drain from the overflow drain hole during normal use adjust slope B Extend the accordion...

Page 10: ...se instructions STEP 6 1 After the unit is installed in the window measure the inner width of one of the accordion panels as shown in Fig 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 2 3 4 5 6 STEP...

Page 11: ...rain holes or slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out REMOVING AC FROM WINDOW Turn AC off and disconnect power cord Remove sash seal f...

Page 12: ...ollow the symbol for the functions you desire BEFORE operating the unit This unit can be controlled by the unit control or the remote control TIMER ECO MODE FILTER On Off Auto Cool Dry Fan Follow me A...

Page 13: ...lluminated and remain on once the mode is selected The unit will automatically initiate the Energy Saver function under COOL DRY and AUTO only AUTO COOLING and AUTO FAN modes TO OPERATE AUTO FEATURE W...

Page 14: ...t throughout the room as needed Pivot horizontal louvers until the desired vertical up down direction is obtained Move the levers from side to side until the desired horizontal left right direction is...

Page 15: ...lacing As an alternative to washing the filter vacuum the filter clean NOTE Never use hot water over 104 F 40 C to clean the air filter Never attempt to operate the unit without the air filter CABINET...

Page 16: ...he coil set to FAN only mode Then set temperature to a higher setting AIR CONDITIONER CYCLING ON AND OFF TOO FREQUENTLY OR NOT ENOUGH Be sure unit is not too large or too small for the area of the roo...

Page 17: ......

Page 18: ......

Page 19: ...The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details...

Page 20: ...Belt Line Rd Suite 878 Dallas TX 75254 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User5PAC10...

Reviews: