background image

3

When removing air filter, do not 
touch metal parts of the unit.

Doing so may cause an injury.

.

Cleaning unit when power is ON 

may cause fire and electric shock

and may cause an injury. 

Operation with windows open may

cause moisture to enter the room.

 

 

 

 

Stop operation and close the
window in severe storms or 
hurricanes.

Do not clean with water.

Water may enter the unit and 

degrade the insulation causing an 

electric shock.

This could injure the pet or plant.

Failure to do so may cause electric

shock and damage.

Do not put a pet or house plant 
where it will be exposed to 
direct air flow.

Hold the plug by the head of the
power plug when taking it out.

Ensure proper ventilation 
especially in rooms with a stove 
or other appliances.

Failure to do so may result in an

oxygen shortage.

This unit is NOT intended to 

preserve precision devices, food, 

pets, plants, and art objects. It may

cause deterioration of quality, etc.

Leaving power on may cause unit 

failure or fire.

Use only as intended.

If unit will not be used for a long
period of time, turn OFF main 
power switch.

 

 

 

 

 

 

If water enters the unit, turn the unit off at the power 
outlet and switch off the circuit breaker. Isolate supply
by taking the power-plug out and contact a qualified 
serviced technician. 

Obstacles may cause appliance 

failure or accident.

Cleaners or detergents may change 

the color or scratch the surface of

the unit.

Do not place obstacles around 
air-inlets or inside of air-outlet.

Use only a soft cloth to clean
the unit.

Prolonged exposure to outdoor

elements may cause damage to

installation bracket causing unit to fall.

There is danger of electric shock.

Periodically check installation
bracket for damage.

.

Operation without secured filters

may cause failure. A dirty filter can 

cause the unit to run inefficiently.

Water from unit contains 

contaminants and could 

cause illness.

Always insert the filters securely. 
Clean filter AT LEAST once 
every two weeks.

NEVER drink water drained from
air conditioner.

Unit and Circuit breaker/fuse
must be switched OFF when
cleaning. 

Do not place heavy objects on the power cord 
and always ensure that the cord is not 
compressed.

Use caution when unpacking 
and installing. 

Sharp edges could cause injury.

!

!

!

!

!

!

!

!

!

!

!

There is danger of fire or electric shock.

!

CAUTION

Summary of Contents for 3PES5000

Page 1: ...fore using your window air conditioner please read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort FOR MODEL 3PES5000 WINDOW AIR CONDITIONER...

Page 2: ...ion of this unit if necessary The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the air conditi...

Page 3: ...ause explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may ca...

Page 4: ...f time turn OFF main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified...

Page 5: ...our Safety Electrical Information The power supply must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset DO NOT store or use gasoline or other flammable vap...

Page 6: ...pinging or switching sounds Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation ELECTRONIC CONTROL OPERATING INSTRUCTIONS TEMP TIMER Check F...

Page 7: ...Auto mode To operate on Fan only Use this function only when cooling is not desired such as for room air circulation or to exhaust stale air You can choose any fan speed you prefer During this functi...

Page 8: ...s after the mode is selected The temperature will then increase cooling or decrease heating units with heater only by another 2O F 1 2O C after an additional 30 minutes This new temperature will be ma...

Page 9: ...ror Unplug the unit and plug it back in If error repeats call consumer services Evaporator temperature sensor error Unplug the unit and plug it back in If error repeats call consumer services is displ...

Page 10: ...nditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on the power cord of the air conditioner Aluminum hous...

Page 11: ...zation and drainage If you are not using the side panels for any reason this pitch to the rear must be maintained A Place unit on floor a bench or a table Hold the accordion panel in one hand and gent...

Page 12: ...g 5 Carefully close the window behind the top rail of the unit Fig 5 NOTE Check that air conditioner is tilted back about 5 8 to 3 4 tilted about 3O to 4O downward to the outside After proper installa...

Page 13: ...slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out Removing AC From Window Turn AC off and disconnect power cord Remove sash seal from between w...

Page 14: ...loth before wiping the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner after unit has dried completely If air conditioner will be stored...

Page 15: ...F 18 C To defrost the coil set to Fan Only mode Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time coolin...

Page 16: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in China 877 365 6274 www pe...