background image

Read these instructions completely

and carefully.

IMPORTANT

- Save these instructions.

IMPORTANT

- Observe all

governing codes and ordinances.

Note to Consumer-

 Keep these

instructions for future reference.

Note to Installer-

 Be sure to leave these

instructions with the Consumer.

Completion time- Approximately 1 hour.

Skill level- Installation of this appliance

requires basic mechanical skills.

We recommend that two people install

this product.
Proper installation is the responsibility

of the installer.
Product failure due to improper installation

is not covered under the Warranty.
You MUST use all supplied parts and use

proper installation procedures as described

in these instructions when installing this air

conditioner.

    BEFORE YOU BEGIN

Do not, under any circumstances, cut or

remove the third (ground) prong from the

power cord.

CAUTION

Do not change the plug on the power cord

of the air conditioner.
Aluminum house wiring may present special

problems- consult a qualified electrician.

When handling unit, be careful to avoid cuts from

sharp metal edges and aluminum fins on front and

rear coils.

TOOLS YOU WILL NEED

Phillips

Screwdriver

Level

TOOLS YOU MAY USE

Screwdriver

Pencil

Ruler or tape measure

Scissors or knife

NOTE: Save carton and these Installation Instructions for future reference.  

            The carton is the best way to store unit during winter or when not in use.

WINDOW REQUIREMENTS

Your air conditioner is designed to install in 

standard double hung windows with opening 

widths of 23 to 36 inches (584 mm to 914 mm).

INNER

Wooden Windows

INSTALLATION INSTRUCTIONS

OFFSET

INTERIOR

WALL

EXTERIOR

WALL

INNER

WINDOW

SILL

9

Summary of Contents for 3PES5000

Page 1: ...fore using your window air conditioner please read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort FOR MODEL 3PES5000 WINDOW AIR CONDITIONER...

Page 2: ...ion of this unit if necessary The air conditioner is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the air conditi...

Page 3: ...ause explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of machine or electric shock Doing so may ca...

Page 4: ...f time turn OFF main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified...

Page 5: ...our Safety Electrical Information The power supply must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset DO NOT store or use gasoline or other flammable vap...

Page 6: ...pinging or switching sounds Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrect installation ELECTRONIC CONTROL OPERATING INSTRUCTIONS TEMP TIMER Check F...

Page 7: ...Auto mode To operate on Fan only Use this function only when cooling is not desired such as for room air circulation or to exhaust stale air You can choose any fan speed you prefer During this functi...

Page 8: ...s after the mode is selected The temperature will then increase cooling or decrease heating units with heater only by another 2O F 1 2O C after an additional 30 minutes This new temperature will be ma...

Page 9: ...ror Unplug the unit and plug it back in If error repeats call consumer services Evaporator temperature sensor error Unplug the unit and plug it back in If error repeats call consumer services is displ...

Page 10: ...nditioner BEFORE YOU BEGIN Do not under any circumstances cut or remove the third ground prong from the power cord CAUTION Do not change the plug on the power cord of the air conditioner Aluminum hous...

Page 11: ...zation and drainage If you are not using the side panels for any reason this pitch to the rear must be maintained A Place unit on floor a bench or a table Hold the accordion panel in one hand and gent...

Page 12: ...g 5 Carefully close the window behind the top rail of the unit Fig 5 NOTE Check that air conditioner is tilted back about 5 8 to 3 4 tilted about 3O to 4O downward to the outside After proper installa...

Page 13: ...slots are not caulked or painted shut Accumulated rain water or condensation must be allowed to drain out Removing AC From Window Turn AC off and disconnect power cord Remove sash seal from between w...

Page 14: ...loth before wiping the controls Excess water in or around the controls may cause damage to the air conditioner Plug in air conditioner after unit has dried completely If air conditioner will be stored...

Page 15: ...F 18 C To defrost the coil set to Fan Only mode Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to Fan Only mode Thermostat is set too cold for night time coolin...

Page 16: ...for Home Comfort Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in China 877 365 6274 www pe...

Reviews: