background image

-9-

Operating The Unit 

(continued)

Removing the collected water: 2 options

OPTION #1: Use the bucket

•  If the bucket is full when the unit is OFF, the full indicator light will illuminate.

•  If the bucket is full when the unit is ON, the compressor will turn off followed 

by the fan 30 seconds later. The full indicator light will flash and the digital 

display will show P2.

•  Slowly pull out the bucket. Grip the left and right handles securely, and 

carefully pull out straight so water does not spill. Do not put the tank on the 

floor because the bottom of the bucket is uneven. The bucket will fall and 

cause the water to spill.

•  Throw away the water and replace the bucket. The bucket must be in place 

securely for the dehumidifier to operate. (Do not drink the water.)

•  The machine will re-start when the bucket is restored in its correct position. 

The unit will take 3 minutes to restart.

OPTION #2: Continuous draining

Water can be automatically emptied into a floor drain by attaching a garden 

hose or dehumidifier drain hose (ID≥Φ5/16") to the dehumidifier. (Hose must 

have a female threaded end with ID: M=1. Hose not included.)

•  Unscrew the plastic cover from the drain outlet on the back of the unit by 

turning the plastic cover counter-clockwise. 

•  If there is water in the continuous drain outlet, dry it thoroughly before 

connecting the hose.

•  Attach the female threaded end of the garden/dehumidifier drain hose to the 

drain hose outlet, then lead the water hose to the floor drain or a suitable 

drainage facility.

•  A hose length of no more than 6 ft. is recommended as the hose must allow 

the water to continuously travel downward into the drain.

•  Make sure the hose is secure to avoid leakage.

•  Direct the hose down toward the drain, making sure that there are no kinks 

that will stop the water flow.

•  Place the end of the hose into the drain and make sure the end of the hose 

is level or down to let the water flow smoothly. 

Never let drain hose go 

upward against gravity.

•  Select the desired humidity setting and fan speed on the unit for continuous 

draining to start.

NOTES:

•  Continuous mode and continuous draining are different. You do not need to 

be on Continuous mode to do continuous draining. See pg. 5 for additional 

information about Continuous mode.

•  When the continuous draining feature is not being used, remove the drain 

hose from the drain hose outlet and dry any water in the drain hose outlet; 

then secure the plastic cover onto the continuous drain outlet. Failure 

to secure the plastic cover onto the drain hose outlet can result in unit 

malfunction, leaking, and/or possible error codes.

OPTION #1: Using & Emptying the Bucket

OPTION #2: CONTINUOUS DRAINING

1. Pull the bucket  

out slightly.

Turn plastic 

cover counter-

clockwise to 

remove

Drain hose

Fig. 5

Fig. 7: 

Fig. 8

Fig. 6

2. Hold both sides of the 

bucket with even strength 

and pull it out from the unit.

3.Dispose of water; replace bucket into proper place.

NOTES:

  •  When you remove the bucket, do not touch any parts inside of the unit. Doing so may damage the product. 

 

•  Be sure to push the bucket gently all the way into the unit. Improper installation or failing to push it in securely  

 

  may cause the unit not to operate.

 

•  When you remove the bucket, be sure to wipe away any excess moisture found inside the unit.

Summary of Contents for 3PAD95

Page 1: ...your dehumidifier please read this manual carefully and keep it for future reference along with your receipt FOR MODEL 3PAD95 DEHUMIDIFIER USER MANUAL Be sure to read the Quick Start Tips on Page 1 C...

Page 2: ......

Page 3: ...session put the unit in an upright position for a minimum of 24 hours before running it 2 When first using the dehumidifier operate the unit on continuous mode for 24 hours 3 After the first 24 hours...

Page 4: ...0 Troubleshooting Tips Troubleshooting tips 11 12 CAUTION Contact an authorized service technician for repair or maintenance of this unit Contact an installer for installation of this unit if necessar...

Page 5: ...unit near a heat source Before cleaning turn off the power and unplug the unit Do not take the water bucket out during operation You should never try to take apart or repair the unit by yourself Disc...

Page 6: ...ailure of appliance and there is danger of electric shock If unit falls over it may spill water and damage belongings or cause electrical shock or fire This will cause unit deterioration due to chemic...

Page 7: ...in 5 increments For drier air press the pad and set to a lower percent value For damper air press the pad and set a higher percent value The recommended standard setting is 45 50 You must be on Normal...

Page 8: ...the first 3 minutes afterwards This is to protect the unit Operation will automatically start after 3 minutes Check Filter Feature The system starts to log the time once the fan motor operates The che...

Page 9: ...ides Drain Hose Outlet Casters Power Cord Plug Band used only when storing unit Air intake filter NOTE All the pictures in the manual are for explanation purposes only The actual shape of the unit you...

Page 10: ...ce that you wish to dehumidify When using the unit When first using the dehumidifier operate the unit in Continuous mode for 24 hours NOTE After the first 24 hours should you wish to set a desired hum...

Page 11: ...than 6 ft is recommended as the hose must allow the water to continuously travel downward into the drain Make sure the hose is secure to avoid leakage Direct the hose down toward the drain making sur...

Page 12: ...d a small amount of mild detergent Swish it around in the bucket empty and rinse NOTE Do not use a dishwasher to clean the bucket After cleaning the bucket it must be securely in place for the dehumid...

Page 13: ...off more frequently Using too small of a unit will cause it to run constantly If the humidity setting and actual humidity in room are cycling right around the same the unit would go off and on accord...

Page 14: ...needs to be emptied The water bucket is not in the proper position UNIT MAKES A LOUD NOISE WHEN OPERATING Make sure the air filter is clean and not clogged Make sure the unit is upright not tilted and...

Page 15: ......

Page 16: ...UILT TO LAST Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 Specification and performance data is subject to change without notice Printed in China 877 365 6274 www perfec...

Reviews: