Relocation

If you move out or if it is desired to relocate the air conditioner, consult your dealer, because special
skills to withdraw Freon, purge air and perform other operations are required.

Location:

Be careful of noise or vibrations

Wire

During cooling operation, the air conditioner will dry the room air, so please fix a pipe to drain all the
water away from the air conditioner.
Please let the indoor unit more than one metre away from the TV set and the radio in order to avoid
the picture and noise interference.
Powerful radio transmitters or any other devices radiating high frequency radio waves can cause 
the air conditioner to malfunction. Please consult the dealer where you purchased the air conditio-
ner before installing it.
Don't fix the unit in the dangerous region with combustible gas or volatile matter.
If the air conditioner operates in an atmosphere containing oils (machine oil), salt (near a coastal 
area), sulfide gas (near a hot spring), etc., such substances may lead to failure of the air conditioner.

Please fix the unit in the stable place to avoid the noise or vibrations.
The noise near the air outlet of the outdoor unit may enter the air exit.
Locate the outdoor unit where noise emitted by it or hot air from its air outlet will cause no nuisance 
to  your neighbours.
If the air conditioner sounds abnormal during operation, contact the dealer where you purchased the
air conditioner.

To avoid the electric shock, please link the air conditioner with the ground. The plug in the air 
conditioner has joined the ground wiring, please don't change it freely.
The power socket is used as the air conditioner specially.
Don't pull the power wiring hard.
When linking the air conditioner with the ground, observe the local rulers.
If necessary, use the power fuse or the circuit, breaker or the corresponding scale ampere.
If you want to change the power wiring, please contact the centre service of the local MD electric 
appliance.

INSTALLATION

8

Special functions

Refrigerant Leakage Detection(optional): 

With this new technology, the dipsplay area will appear  EC  (if applicable)  and the LED 
indication lamps continue flashing when the outdoor unit detects refrigerant leakage. 

Louver Angle Memory Function(optional): 

For some models, the machine is special designed with louver angle memory function.

 

Power 

failure during operation or pressing the ON/OFF button on the remote 

control

 will stop the unit 

completely.When the power restores or pressing the ON/OFF button on the remote 

control

 

again,the unit restarts automatically with  the previous open angle of the horizontal louver by the 
memory function.So we strongly recommend that the open angle of the horizontal louver should 
not be set too small,in case the condensed water forms and drops from the horizontal louver. 
Press the Manual control button and the open angle of the horizontal louver will be restored to 
the standard angle.

Summary of Contents for 2PAMSCH09

Page 1: ...ETTE AB SERIES HEAT PUMP USER MANUAL FOR MODELS 2PAMSCH09 2PAMSCH12 2PAMSCH18 MULTI ZONE Before using your air conditioner please read this manual carefully and keep it for future reference along with...

Page 2: ...RMATION 1 HINTS FOR ECONOMICAL OPERATION 2 PART NAMES 3 MANUAL OPERATION 4 ADJUSTING AIR FLOW DIRECTION 4 MAINTENANCE 5 AIR CONDITIONER OPERATION AND PERFORMANCE 7 INSTALLATION 8 TROUBLESHOOTING 9 TRO...

Page 3: ...ir conditioner is in use especially if there is also a gas appliance in use in this room Failure to follow these directions may result in a loss of oxygen in the room To prevent electric shock turn of...

Page 4: ...more often than necessary Set the timer for the desired operating time Never put obstructions near the air outlet or the air inlet Or it will cause lower efficiency even a sudden stop If you don t pla...

Page 5: ...receiver n operation lamp 3 o timer indicator p PRE DEF indicator cooling and heating type or fan only indicator cooling only type q alarm indicator PART NAMES f b d e i m n l o p c q a j k e g d e Di...

Page 6: ...or 30 minutes The remote control operation is disabled OFF The OPERATION lamp goes off The air conditioner is OFF while the remote control operation is enabled 1 2 3 4 ADJUSTING AIR FLOW DIRECTION Cas...

Page 7: ...vents for cleaning These may cause the plastic surface to crack or deform Checks before operation Cleaning the air filter Check that the wiring is not broken off or disconnected Check that the air fil...

Page 8: ...must be pulled off before doing as indicated above Cassette Type 6 2 Take out the air in grill together with the air filter shown in Sketch B Pull the air in grill down at 45 o and lift it up to take...

Page 9: ...run the air conditioner under the following temperature conditions Mode Cooling operation Heating operation Drying operation Temperature 1 If air conditioner is used outside of the above conditions ce...

Page 10: ...contact the dealer where you purchased the air conditioner To avoid the electric shock please link the air conditioner with the ground The plug in the air conditioner has joined the ground wiring ple...

Page 11: ...The air inlet or outlet of the outdoor unit is blocked Doors or windows are open The air filter is clogged with dust The louver is not at the correct position The fan speed is set to low The temperat...

Page 12: ...whether the timer operation has come to an end when the OFF TIMER is indicated on the display Check whether the timer operation is started when the ON TIMER is indicated on the display The air conditi...