Malfunction

1

2

3

4

5

6

7

8

9

10

12

13

14

15

16

17

18

19

20

21

22

23

24

25

11

Indoor EEPROM error

Water-level alarm malfunction

Indoor room temperature sensor 
open circuit or short circuit

Indoor fan speed malfunction

Communication malfunction 
between two indoor units (for 
twins model)

Refrigerant leakage detection 
malfunction 

Evaporator coil temperature 
sensor open circuit or short circuit

Other malfunction of twins model

Outdoor room temperature sensor 
open circuit or short circuit

Current overload protection

High/Low voltage protection

Inverter module IPM protection

Lifting panel is not closed

Lifting panel malfunction 

Lifting panel communication 
checking channel is abnormal

T2b sensor error

Outdoor EEPROM error

Outdoor fan speed malfunction 
(Only for DC fan motor)

Discharging air temperature 
sensor error

Outdoor condenser pipe 
temperature sensor error

E0.

E1.

E3.

E4.

E5.

EC.

EE.

E8.

E9.

F0.

F1.

F2.

F3.

F4.

F5.

F6.

F7.

F8.

F9.

P0.

P1.

P2.

P3.

P4.

P5.

    
ON.

    
ON.

ON.

ON.

ON.

    
ON.

ON.

    
ON.

ON.

    
ON.

           
Flash.

           
Flash.

Flash.

Flash.

           
Flash.

           
Flash.

High temperature protection of 
compressor top

Mode conflict

Compressor drive error

Outdoor low temp. Protection

The following displays indicate an error or problem:

The displayed error code differs from appliance to appliance. The actual display of the indoor 
unit shall prevail.

NO

Display (nixie tube)

timer lamp running lamp (flashes per second)

Communication malfunction 
between indoor and outdoor units

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

    

1

    

2

    

4

    

5

6

7

    

8

9

10

1

    

2

3

4    

5

    

6

    

7

    

8

    

9

1

10

1

2

    

3

    

4

5

6

16122500000082 
20150328

The design and specifications are subject to change without prior notice for product improvement. 
Con

tact

 

844-472-2473 for details.

PA/Manual/01

15

2018

 

QSBPQ4U-024AEN(A3)

Summary of Contents for 2PAMSCH09

Page 1: ...ETTE AB SERIES HEAT PUMP USER MANUAL FOR MODELS 2PAMSCH09 2PAMSCH12 2PAMSCH18 MULTI ZONE Before using your air conditioner please read this manual carefully and keep it for future reference along with...

Page 2: ...RMATION 1 HINTS FOR ECONOMICAL OPERATION 2 PART NAMES 3 MANUAL OPERATION 4 ADJUSTING AIR FLOW DIRECTION 4 MAINTENANCE 5 AIR CONDITIONER OPERATION AND PERFORMANCE 7 INSTALLATION 8 TROUBLESHOOTING 9 TRO...

Page 3: ...ir conditioner is in use especially if there is also a gas appliance in use in this room Failure to follow these directions may result in a loss of oxygen in the room To prevent electric shock turn of...

Page 4: ...more often than necessary Set the timer for the desired operating time Never put obstructions near the air outlet or the air inlet Or it will cause lower efficiency even a sudden stop If you don t pla...

Page 5: ...receiver n operation lamp 3 o timer indicator p PRE DEF indicator cooling and heating type or fan only indicator cooling only type q alarm indicator PART NAMES f b d e i m n l o p c q a j k e g d e Di...

Page 6: ...or 30 minutes The remote control operation is disabled OFF The OPERATION lamp goes off The air conditioner is OFF while the remote control operation is enabled 1 2 3 4 ADJUSTING AIR FLOW DIRECTION Cas...

Page 7: ...vents for cleaning These may cause the plastic surface to crack or deform Checks before operation Cleaning the air filter Check that the wiring is not broken off or disconnected Check that the air fil...

Page 8: ...must be pulled off before doing as indicated above Cassette Type 6 2 Take out the air in grill together with the air filter shown in Sketch B Pull the air in grill down at 45 o and lift it up to take...

Page 9: ...run the air conditioner under the following temperature conditions Mode Cooling operation Heating operation Drying operation Temperature 1 If air conditioner is used outside of the above conditions ce...

Page 10: ...contact the dealer where you purchased the air conditioner To avoid the electric shock please link the air conditioner with the ground The plug in the air conditioner has joined the ground wiring ple...

Page 11: ...The air inlet or outlet of the outdoor unit is blocked Doors or windows are open The air filter is clogged with dust The louver is not at the correct position The fan speed is set to low The temperat...

Page 12: ...whether the timer operation has come to an end when the OFF TIMER is indicated on the display Check whether the timer operation is started when the ON TIMER is indicated on the display The air conditi...

Page 13: ...lfunction Only for DC fan motor Discharging air temperature sensor error Outdoor condenser pipe temperature sensor error E0 E1 E3 E4 E5 EC EE E8 E9 F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 P0 P1 P2 P3 P4 P5 ON O...

Page 14: ...Specification and performance data is subject to change without notice Printed in China 844 472 2473 www perfectaire us Distributed by Perfect Aire LLC 5401 Dansher Rd Countryside IL 60525...

Reviews: