IMPORTANT: Only trained, qualified personnel should access electrical panel on unit and install electrical

accessories. Please contact your local electrical contractor, dealer, or distributor for assistance. 

Thermostat Wire Routing

NOTE:

Thermostat wire is field supplied. Recommended

wire gauge is 18 to 20 gauge solid thermostat wire.

It is recommended that extra wires are run

to unit in case any are damaged during installation.

Thermostat wire should always be routed around

or under, NEVER through, the wall sleeve. The

wire should then be routed behind the front panel

to the easily accessible terminal connector.

THERMOSTAT WIRE ROUTING

(UNDER SLEEVE, BEHIND FRONT PANEL)

Fig. A - Proper Wire Routing Beneath Unit

NOTE: Refer to thermostat installation instructions

for details on installing wall thermostat.

Terminals for manufacturer 

provided wall thermostat

*S9 dip switch in 

 OFF (DOWN) 

 position.

*S9 dip switch in 

 ON (UP) position.

Remove the two screws

Cover panel

Terminals for universal 

wall thermostat

WALL THERMOSTAT TERMINAL

INSTALLATION OF WALL THERMOSTAT PROVIDED 

BY THE AIR CONDITIONER’S MANUFACTURER

NOTE:

 When installing a thermostat provided by the 

air conditioner’s maufacturer, refer to the specific 

instructions included with the thermostat.

IMPORTANT NOTE:

 When installing a thermostat 

provided by the air conditioner’s manufacturer, the 

S9 dip switch must be in the ON (UP) position.

Insert the wire connector of the wall thermostat into 

the relevant terminal according to different shape as 

shown below.

INSTALLATION OF UNIVERSAL 

WALL THERMOSTAT

NOTE:

 When installing a universal wall thermostat, 

refer to the specific instructions included with the 

thermostat chosen.

IMPORTANT NOTE:

 When installing a universal 

wall thermostat, the S9 dip switch must be in the 

OFF (DOWN) position.

Remove the two screws as shown below to access 

the terminals behind the cover panel.

TERMINAL DESIGNATION

FC(L)

Front desk control terminal L

FC(N)

Front desk control terminal N

LOW-FAN

Low fan speed

HI-FAN

High fan speed

4-WAY

4-way valve

(For heat pump system)

HEAT2

Electrical heater 2

HEAT1

Electrical heater 1

COMP

Compressor

24V(N)

24VAC terminal N

24V(L)

24VAC terminal L

Summary of Contents for 1PTC07A-3.5

Page 1: ...read this manual carefully and keep it for future reference along with your receipt Your Source for Home Comfort PACKAGED TERMINAL AIR CONDITIONER USER MANUAL FOR MODELS 1PTC07A 3 5 1PTC09A 3 5 1PTC12...

Page 2: ...ferring to this section may save time and prevent the need for a service call in the event of a problem CAUTION Contact an authorized service technician for installation repair or maintenance of this...

Page 3: ...may cause fire Failure to do so may cause explosion fire and burns Doing so may cause electric shock or fire due to heat generation Doing so may cause electric shock Doing so may cause failure of mach...

Page 4: ...main power switch If water enters the unit turn the unit off at the power outlet and switch off the circuit breaker Isolate supply by taking the power plug out and contact a qualified serviced technic...

Page 5: ...age within the airconditioner Do not use an extension cord or an adaptor plug WARNING DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance A...

Page 6: ...LED for POWER indicates the unit s ON OFF status If the unit is in ON mode the LED will be green If the unit is OFF the LED will be off Note HEAT mode is for models with Cooling Heating functions only...

Page 7: ...ature of the unit in cooling or heating mode The temperature can be set by increments of 1 F 1 C The temperature setting appears in the display NOTE Press and hold the and buttons together for 3 secon...

Page 8: ...e in continuous or cycle mode while the unit is in heating and cooling mode CON Continuous Allows the fan to run continuously circulating air even when the temperature setting has been satisfied This...

Page 9: ...sal wall thermostat WALL THERMOSTAT TERMINAL INSTALLATION OF WALL THERMOSTAT PROVIDED BY THE AIR CONDITIONER S MANUFACTURER NOTE When installing a thermostat provided by the air conditioner s maufactu...

Page 10: ...k If High fan is desired wire the G output from the thermostat to HI FAN on the unit s terminal block The range of set temperature of the wall thermostat must be in accordance with the unit type heat...

Page 11: ...reme care should be used to avoid serious cuts The air conditioner is heavy Always use 2 people when lifting or moving unit COOLED AIR INTAKE AIR WALL WALL HEAT RADIATION SLEEVE Over 20 Fig 2 Fig 3 Fi...

Page 12: ...holes See Fig 7 and Fig 8 Reinstall front panel See Fig 9 Place tabs over top rail Push Inward at bottom until panel snaps into place NOTE When vent control lever set at CLOSED only the air inside the...

Page 13: ...e or with damaged filter will allow dirt and dust to reach indoor coil and reduce cooling heating airflow and efficiency of unit Airflow restriction may cause damage to unit Do not UNIT DAMAGE HAZARD...

Page 14: ...ately 3 minutes for compressor to start Strange numbers characters appear on the display The unit may be in a protection mode The unit may be set for C instead of F The unit is making noises Clicking...

Page 15: ...Printed in PRC...

Reviews: