DIP SWITCH CONFIGURATIONS
Fig. 2
-
Pull out at the bottom to release
it from the tabs .
- Then lift up .
UP (ON)
DOWN (OFF)
Fig. 4
Dip Switches
Fig. 3
● REMOVING THE FRONT PANEL
- Dip switch controls are located behind the front panel through
an opening below the control panel. To access, remove the
front panel. See Fig. 2.
- Dip switches are accessible without opening the control box.
See Fig. 3.
- Unit must be powered OFF to effectively change their status.
● DIP SWITCH CONFIGURATIONS
- See Table 1 and Fig. 4 for Dip Switch configurations and
functions of each dip switch position.
NOTE:
On heating mode, the setting temperature
cannot be higher than 84ºF/29ºC.
● Electric Heat Only (for heat pump unit only)
This setting is typically used for emergency heating.
● Enable Wall Thermostat
A wired wall themostat can be connected to the
unit. If one is connected, this dip switch must be
moved to the Enable Wall Thermostat position
before the wall thermostat will begin control.
● Setpoint Temperature Limits
Provides a restricted range of temperature control.
● Heat and Cool Fan CON/CYC Dip-switches
Allows the fan to operate in continuous or cycle
mode while the unit is in heating and cooling mode.
CON (Continuous)
Allows the fan to run continuously, circulating air
even when the temperature setting has been
satisfied. This switch helps to maintain the room
temperature closer to the thermostat setting.
CYC (Cycle)
This setting allows the fan to cycle on and off with
the compressor or electric heater. The fan stops a
short time after the temperature setting is satisfied.
Wall thermostat type
Heating type
Temperature display type
Control type
Setpoint limit 1
Setpoint limit 2
Fan CON/CYC for heating
Fan CON/CYC for cooling
Table 1 – DIP SWITCH CONFIGURATIONS
No.
UP (ON)
DOWN (OFF)
Notes
S1
Electric Heat Only
Electric Heat and Pump Heat
For Heat Pump unit only
S2
Temperature Display in °C
Temperature Display in °F
S3
Enable Wall Thermostat
Enable Control Panel
S4*S5
S4 UP (ON) & S5 UP (ON) = 61°F–86°F (16°C–30°C);
S4 UP (ON) & S5 DOWN (OFF) = 65°F–78°F (18°C–26°C)
S4 DOWN (OFF) & S5 UP (ON) = 63°F–80°F (17°C–27°C);
S4 DOWN (OFF) & S5 DOWN (OFF) = 68°F–75°F (20°C–24°C)
combine to select set point range.
S6
Fan Continuous Run for Heating Fan Cycle for Heating
S7
Fan Continuous Run for Cooling Fan Cycle for Cooling
S9
Manufacturer’s wall thermostat
Approved universal
wall thermostat
Consult with the sales agency or
manufacturer for details.
7