background image

2

IMPORTANT SAFEGUARDS

Utilize two or more people to lift and install the unit. 

Be sure all accessories are removed from the packing before use.

To avoid possible injury

avoid contact with the metal parts of the appliance when removing or re-

installing the filter. It can result in the risk of personal injury.

Do not block the air inlet or outlet of the appliance. Reduced air flow will result in poor 

performance and could damage the unit.

Always grasp the plug when plugging in or unplugging the appliance. Never unplug by pulling 

on the cord. It can result in the risk of electrical shock and damage.

Install the appliance on a sturdy level floor capable of supporting up to 110lbs(50kg). 

Installation on a weak or unlevel floor can result in the risk of property damage and personal  

injury.

Close all doors and windows to the room for most efficient operation.

GWP:  R410A: 2088,   R134a: 1430,   R290: 3

IMPORTANT - GROUNDING METHOD

       This product is factory equipped with a power supply cord that has a three-pronged 

grounded plug. It must be plugged into a mating grounding type receptacle in accordance 

with the National Electrical Code and applicable local codes and ordinances. If the circuit 

does not have a grounding type receptacle, it is the responsibility and obligation of the 

customer to exchange the existing receptacle in accordance with the National Electrical 

Code and applicable local codes and ordinances. The third ground prong should not, 

under any circumstances, be cut or removed. Never use the cord, the plug or the appliance 

when they show any sign of damage. Do not use your appliance with an extension cord 

unless it has been checked and tested by a qualified electrical supplier. Improper 

connection of the grounding plug can result in risk of fire, electric shock and/or injury to 

persons associated with the appliance. Check with a qualified service representative if in 

doubt that the appliance is properly grounded.

ELECTRICAL CONNECTIONS

The mains power supply corresponds to the value indicated on the rating plate on 

the back of the appliance.

The power socket and electrical circuit are adequate for the appliance.

The mains socket matches the plug. If this is not the case, have the plug replaced.

The mains socket is adequately earthed. Failure to follow these important safety 

instructions absolves the manufacturer of all liability.

Before plugging the appliance into the mains socket, check that:

Summary of Contents for 1PAD8

Page 1: ...DEHUMIDIFIER FOR MODEL 1PAD8 Before using your dehumidifier please read this manual carefully and keep it for future reference along with your receipt USER MANUAL...

Page 2: ...electric shock Do not disassemble or modify the appliance or the power cord it can result in the risk of electric shock or fire All other services should be referred to a qualified technician Do not...

Page 3: ...onal Electrical Code and applicable local codes and ordinances If the circuit does not have a grounding type receptacle it is the responsibility and obligation of the customer to exchange the existing...

Page 4: ...water in the form of vapor This determines the level of humidity in an atmosphere The capacity of the air to hold water vapor increases with temperature This is why in homes as soon as the temperatur...

Page 5: ...anel 2 Intake grille 3 Bucket 4 Winding hole Note All diagrams in this manual are schematic and may differ slightly from actual use 5 Water level view window 6 Power cord 7 Air outlet grille 8 Handle...

Page 6: ...rom it 2 Install the drain cover cap on the bucket Note Be sure unit sits in proper position for 24 hours before use Control Panel 1 Timer symbol 2 Bucket full symbol A Timer button B Increase button...

Page 7: ...l you expect to achieve or set the time when using timer setting Mode selection Press the button to turn on the appliance and press the MODE button to browse different modes Press the MODE button unti...

Page 8: ...is running press the button When the symbol starts to flash press the to adjust the set time between 0 5 24 hours Within 5 seconds without operation press the timer start function it will display the...

Page 9: ...e bucket 1 Put the unit on level floor take out the bucket remove the chip of bucket 2 Install the pipe on drain nozzle which can be found inside of the unit 3 Place bucket correctly and assure the dr...

Page 10: ...nt to help prevent moisture damage 7 The dehumidifier must be operated in an enclosed area to be most effective 8 Close all doors windows and other outside openings to the room CLEAN AND MAINTENANCE B...

Page 11: ...never be hotter than 104 After washing leave the filter to dry and attach the intake grille to the appliance END OF SEASON OPERATIONS To unplug from the mains socket empty the bucket Clean the filter...

Page 12: ...irflow is restricted Dirty filter The Humidity Control may not be set low enough Doors and windows may not be closed tightly Clothes dryer may be blowing moist air into the room Room temperature is to...

Page 13: ...y disappear in 60 min This is normal Check the drain connection if the appliance is at level If using the water tank remove the drain pipe and put back the drain cover or install the drain pipe correc...

Page 14: ...LLC 5401 Dansher Rd Countryside IL 60525 Distributed by 844 4PA AIRE 844 472 2473 www perfectaire us Specification and performance data is subject to change without notice Printed in China PA User_1P...