Installation and Operation Manual for the

 Perenio® 

PEACG01 Control Gateway 

 

 

Doc Version: 2.0.0 

 

©Perenio IoT spol s r.o. All Rights Reserved

 

 

Page 

10

 of 

32

 

 

1.2 Technical Specification 

Table 2 

– 

Basic Technical Specifications of the Control Gateway 

Parameter 

Value 

Item Number 

PEACG01 

Operating System 

Linux 

Communication 
Technology 

Wi-Fi (IEEE 802.11b/g/n), ZigBee 3.0 (IEEE 802.15.4), 
Ethernet (10/100Mbps RJ-45) 

Bit Rate 

802.11b (11 Mbps max), 802.11g (54 Mbps max), 
802.11n (300 Mbps max), 802.15.4 (250 Kbps) 

WEP/WPA2 Encryption 

Support of 128-bit encryption 

Supported Protocol 

TCP/IP 

IoT Protocols 

MQTT and CoAP 

Compatibility 

iOS (10.1 and higher) and Android (4.4 and higher) 

SoC 

QCA4531 (Wi-Fi), EFR32/Cortex-M4 (ZigBee) 

Flash Memory 

NAND Flash: 128MB 
NOR Flash: 512KB 

ZigBee Coverage 

up to 40 m (open area) 

ZigBee Antenna 

Type: Built-in 
Max RF Output Power: 10dBm 
Receiver Sensitivity: -93dBm 
Antenna Gain: 1dBi 

Wi-Fi Antenna 

Type: Built-in 
Max RF Output Power: 16dBm 
Receiver Sensitivity: -83dBm 
Antenna Gain: 2.5dBi 

Operating Frequency Band 

2400MHz – 2483.5MHz 

Server 

Remote Server 

Power 

Output: DC 5V/0.7A 
Power Consumption: 5W (max) 

Operating Temperature 

0°C to +40°C 

Summary of Contents for PEACG01

Page 1: ...Installation and Operation Manual for Perenio PEACG01 Control Gateway June 2019 ...

Page 2: ......

Page 3: ...l materials under Perenio tradename contained therein are protected in accordance with international and local laws including Acts on copyrights and related rights Any reproduction copying publication as well as further distribution or public display of materials contained in the present document whether in full or in part shall not be allowed until an appropriate permission of the copyright owner...

Page 4: ...m the use of an outdated version of the document as well as for any possible technical and or typographical errors either omitted or accidental or any related damage that may result from the document transfer or the use of devices Perenio IoT shall make no guarantee with respect to any data contained herein including but not limited to the device merchantability and fitness for a particular purpos...

Page 5: ...1 65 EU Directive The device complies with the requirements to the level of electromagnetic interference by the Federal Communications Commission The national conformity mark of the Ukraine indicating that the device meets requirements of all applicable technical regulations The device and supplied batteries must not be disposed of as a household waste in accordance with the Waste Electrical and E...

Page 6: ...al Specification 10 1 3 Scope of Delivery 11 1 4 Packaging and Labelling 12 1 5 Safe Operation Rules 12 1 6 Why ZigBee 13 2 Installation and Setup 14 2 1 Initial Installation and Configuration 15 2 2 Reset to Factory Settings 21 2 3 Ethernet Connection 21 2 4 Wi Fi Router Frequency Settings 22 2 5 Changing the Room or Location for the Control Gateway 22 2 6 History and Push Notifications 23 3 Main...

Page 7: ...twork 13 Figure 5 Example of the PEACG01 Control Gateway Installation 14 Figure 6 Add new device procedure The CG activation process 20 Table 1 Control Gateway LED Indicator Statuses 9 Table 2 Basic Technical Specifications of the Control Gateway 10 Table 3 Typical Errors and Troubleshooting Methods 31 Connection to the Perenio Smart Mobile App A INSTALLATION OF THE PERENIO SMART MOBILE APP 15 B D...

Page 8: ...f alarm The Control Gateway searches for and manages devices via the Mobile App Key features of the PEACG01 Control Gateway are as follows Support for Wi Fi Ethernet and ZigBee iOS 10 1 and higher and Android 4 4 and higher smartphone compatibility Possibility to connect up to 100 devices located within the radius of 40 m Support for cloud services collection and analysis of data Remote control vi...

Page 9: ...trol Gateway to the Ethernet router Table 1 Control Gateway LED Indicator Statuses Indicator Status Description WAN Indicator Light is on The CG is connected to the Remote Server Light is off The CG is disconnected from the Remote Server LAN Indicator Light is on The CG is Ethernet connected to the network Light is off The CG is not Ethernet connected to the network Power Indicator Light is on The...

Page 10: ...ps max 802 15 4 250 Kbps WEP WPA2 Encryption Support of 128 bit encryption Supported Protocol TCP IP IoT Protocols MQTT and CoAP Compatibility iOS 10 1 and higher and Android 4 4 and higher SoC QCA4531 Wi Fi EFR32 Cortex M4 ZigBee Flash Memory NAND Flash 128MB NOR Flash 512KB ZigBee Coverage up to 40 m open area ZigBee Antenna Type Built in Max RF Output Power 10dBm Receiver Sensitivity 93dBm Ante...

Page 11: ...rizontal surface For indoor installation only Casing Material PC Polycarbonate Color White Dimensions L x W x H 110 x 110 x 31 mm Weight 123 7 g 259 g with accessories Warranty Period 24 months Service Life 24 months Certification CE EAC RoHS UA TR Data Protection GDPR Compliance 1 3 Scope of Delivery The following items and accessories are supplied within the Perenio PEACG01 Control Gateway packa...

Page 12: ...fe Operation Rules For the proper and safe operation of Perenio Control Gateway follow the instructions and safety procedures described in the present Manual The Manufacturer shall not be liable for any damage caused as a result of improper operation of devices Safe Operation Conditions 1 The device shall be installed indoors only 2 Users shall observe storage transportation conditions as well as ...

Page 13: ... increases the reliability and flexibility of the system making it possible to install sensors at larger distance from the Control Gateway even in the presence of obstacles for example reinforced concrete walls It should also be noted that the ZigBee Protocol has several levels of security and uses the AES 128 encryption algorithm used by banking and government agencies which indicates a high degr...

Page 14: ... high level of noise and a high frequency interference Reinforced concrete floors may reduce the distance of wireless signal transmission It is recommended to install the Control Gateway so that it is at the minimum possible distance from sensors Below see possible locations for the Control Gateway Figure 5 Example of the PEACG01 Control Gateway Installation Images of accessories are provided for ...

Page 15: ... data See par C as well as par 2 4 for the suitable Network frequency selection 5 Enter the desired Control Gateway name Location and Room See par D below ATTENTION The Device must not be switched off or disconnected from the mains for at least 5 MINUTES after the RESET Button is pressed as well as for at least 10 MINUTES after the firmware update process is started A INSTALLATION OF THE PERENIO S...

Page 16: ...ivacy Policy and provisions for personal data protection accessible by the link c Click on the SIGN UP button The User will receive an email to verify the User Account follow the link d Login to the User Account A 2 LOGIN TO THE EXISTING USER ACCOUNT a Enter your e mail address and password in the login screen b Click on the LOG IN button NOTE If the password was lost the User can restore it by cl...

Page 17: ... the icon in the upper right corner of the Devices tab and select Wi Fi Devices from the list See Figure 6 b Click on the SCAN QR CODE button c Confirm the permission to access your Control Gateway in the pop up window It may not be available for certain smartphone models d Find the QR Code sticker on the back of the Quick Start Guide supplied with the CG or on the bottom of the CG and place the s...

Page 18: ...o the QR Code c Click on the CONNECT button C SENDING WI FI NETWORK DATA TO THE DEVICE Do as follows after the screen to connect the device to the Wi Fi Network will be displayed a Enter the password from the Wi Fi Network or select another Network NOTE The device may be connected to Wi Fi Network of 2 4 GHz only b Click on the CONNECT button NOTE Before connecting make sure that the CG is powered...

Page 19: ...ID and or password or Wi Wo Network data was entered incorrectly d Internet Provider failures NOTE To eliminate connection failures follow instructions specified on corresponding screens of the smartphone D LOCATION AND ROOM SETTING After successful connection of the device the User may specify the following a Device name b Device Location c Room You can also select an image for the device by clic...

Page 20: ...ion Manual for the Perenio PEACG01 Control Gateway Doc Version 2 0 0 Perenio IoT spol s r o All Rights Reserved Page 20 of 32 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Figure 6 Add new device procedure The CG activation process ...

Page 21: ...le Wi Fi Networks as an Access Point or until both the WAN and the Power Indicators light up For cases when the device was already activated in the Mobile App As a rule the reset to factory settings shall not take more than three 3 minutes After completion of the reset process the Control Gateway is considered ready for operation or reactivation in the Mobile Application NOTE The reset to factory ...

Page 22: ...ollowing options are possible 1 Change the room location The Wi Fi Network remains the same a Disconnect the Control Gateway from the mains The status of the device will be changed to Offline b Move the CG to another room location and connect it to the mains c Wait until the Control Gateway is rebooted It usually takes no more than 2 minutes and the status of the device is changed to Online d Chan...

Page 23: ...on a smartphone as well as recorded in the notification window and in the History tab in the Mobile Application Important messages These are recorded in the notification window in the Armed Mode as well as always recorded in the History tab Standard events These are recorded in the History tab only Alarms The most important messages such as device actuation notifications when in the Armed mode inc...

Page 24: ...m dirt and dust at least once every six months Check for updates of the Perenio Smart app Check for the power adapter condition and replace it in a timely manner Repair mechanical damages to devices in Service Centers The Perenio Control Gateway repairs shall be carried out in Service Centers because casings will have to be opened in the case of any element failure In the case of warranty repairs ...

Page 25: ...e shall be the date indicated on the sales cashier s receipt or other relevant document If the date of sale is not possible to be determined the start of the warranty period shall be the date of manufacture of the device The Manufacturer shall guarantee that all materials components and assemblies of Perenio devices are free from defects under normal operation within the warranty period The limite...

Page 26: ... Installation and Operation Manuals In the event when the Serial Number Name Plates the date of manufacture or the Model name on the device casing was in any way removed erased affected altered or made illegible In the case of violation of operating procedures and conditions as well as the device installation instructions described in relevant Manuals Cracks scratches and other defects caused as a...

Page 27: ...n legal rights The Customer may also have other rights in accordance with the local consumer protection laws that vary from country to country and may not coincide with this limited warranty For full understanding of the Customer s rights you shall read local acts NOTE The Manufacturer does not produce equipment for Vital Tasks Vital Task Products shall include life support systems medical equipme...

Page 28: ...ecifications of the present Manual For disposal of devices and or batteries the User shall observe the rules of the Directive on Waste Electrical and Electronic Equipment WEEE according to which all electric and electronic products as well as batteries must be disposed of separately at the end of their service life Such devices and accessories must not be disposed of together with unsorted municip...

Page 29: ...uring Plant Name LEEDARSON LIGHTING CO LTD Address Xingtai Industrial Zone Economic Development Zone Changtai County Zhangzhou City Fujian Province China Importing Company Croatia Name ASBISc CR d o o Address Slavonska avenija 24 6 10000 Zagreb RH Czech Republic Name ASBIS CZ s r o Address Obchodní 103 Čestlice 25101 Poland Name ASBIS POLAND Sp z o o Address Ul Szyszkowa 43 02 285 Warszawa Quality...

Page 30: ... Rights Reserved Page 30 of 32 Czech Republic Name ASBIS CZ s r o Address Obchodní 103 Čestlice 25101 Poland Name ASBIS POLAND Sp z o o Address Ul Szyszkowa 43 02 285 Warszawa Info on Certificates and Declarations Certificates Declarations Addresses of Service Centers are available at perenio com in the Support Section ...

Page 31: ... Gateway Restore factory settings See par 2 2 herein 2 The Control Gateway does not power up Failure of the power supply of incorrect power supply range Check power supply connections or power supply range 3 The CG does not activate in the app when Ethernet connected It is the initial connection of the CG or failure of the CG network The initial connection of the CG shall be to Wi Fi For further c...

Page 32: ...well as solid bodies larger than 12 mm Such device is protected from vertically falling drops and condensation and is suitable for unheated rooms Location General designation of a building or premises where the Perenio Control Gateway Perenio Smart Software developed by Perenio IoT for remote control of devices from smartphones QR Code The quick response code which represents a matrix barcode cont...

Reviews: