Do not extend the included cable as this can lead to a high voltage loss or cable
overheating!
Step 3: Connect the device.
You can extend the connection cable to the device without problems.
Step 4: switch on the inverter.
The green LED lights up. The inverter delivers an output power of 230VAC.
Step 5: Switch on the connected device.
Respect the order of the aforementioned steps. To switch off the system, proceed in reverse order.
6.
Earthing
The rear panel of the inverter is equipped with a terminal fitted with a wing nut. This terminal is
connected to the case of the inverter and also to the earthing terminal of the AC output socket.
The chassis earthing lug should be connected to an earthing point, which will vary depending on
where the power inverter is installed. In a vehicle, connect the chassis ground lug to the chassis of
the vehicle. In a boat, connect to the boat's grounding systems. In a fixed location, connect to
earth.
7.
Measuring AC Voltages
The output wave of the AC inverter is a MODIFIED SINEWAVE. An AUTHENTIC RMS VOLT METER is
required to measure the AC output voltage. Using any other type of voltage measuring device will
result in an AC voltage reading that is up to 20 to 30V lower than the rated value. Only an authentic
RMS voltmeter provides an accurate reading.