![Pereko KSP Duo Operation And Maintenance Manual Download Page 79](http://html1.mh-extra.com/html/pereko/ksp-duo/ksp-duo_operation-and-maintenance-manual_1528311079.webp)
PAGE • 7
User’s manual for screw-conveyor feeder Quatro PSQ
3.2.1 PELLET COMBUSTION
In case of combustion of light pellet, e.g. made of straw, it is necessary to use post-combustion angle
bar,
fi
g. 3, which prevents too early falling of the pellet to the ash-pan.
K
ą
townik dopalaj
ą
cy
Post-combustion angle bar
Figure 3.
Assembly of post-combustion angle bar
3.3. Shutdown
Shutdown fan and feeder to shutdown a boiler. Wait until the
fl
ame goes out and push heat to ash-
pan (manual operation on the controller).
3.4. Rupture of split pin
If the split pin is ruptured: 1) switch o
ff
the motoreducer on motor to “0” position”; 2) knock out old
split pin; 3) centre hole of the endless screw with hole of the motoreducer sleeve using a wrench;
4) insert new split pin (screw M5 5.8); 5) empty the container using cleaning holes located below
and start the endless screw by changing the direction of its rotations to reverse. After pushing out the
fuel you should switch the direction of revolutions of the motoreducer to allow feeding.