Operation and maintenance manual for the AGRO Multi series boilers with feeders. The producer reserves the right to introduce technical modifications.
2.2.5. Forced draught fan
Forced draught fan is intended to supply su
ffi
cient amount of
air to the furnace. Amount of supplied air varies and it is au-
tomatically controlled by the controller. Detailed information is
contained in the
Forced draught fan user’s manual
enclosed to
the boiler documentation.
2.2.6. Set of feeder with burner
Feeder unit with the burner is driven by the motoreducer and
it is installed on the left or the right side of the boiler. Its task is
to take the fuel from the container and feed it automatically to
burner part. PSQ trough burner is used in the AGRO Multi boiler
series.
Design of the unit allows quick assembling and disassem-
bling. Fuel container with tightly closed cover is installed on the
feeder unit. Detailed information is contained in the
Feeder user’s
manual
enclosed in the boiler documentation.
2.2.7. Outlet water connection
Outlet water connection is a connection to the central heating
system on the hot water side.
2.2.8. Return water connection
Return water connection is a connection of boiler to the cen-
tral heating system on the cold water side returning from the
system.
2.2.9. Flue with a damper
Flue with rotary
fl
ue gas damper is an integral part of the boiler,
which discharges
fl
ue gas towards the chimney
fl
ue.
2.2.10. Flue gas swirlers
Flue gas swirlers are located inside the convection ducts to swirl
fl
ue gas stream, what has an in
fl
uence on the increase of e
ffi
-
ciency and the boiler power. They should be removed in case of
weak chimney draught.
2.2.11. Water tubes
Water tubes (only AGRO Multi 12) are steel components
fi
lled
with water permanently located in the convection ducts. Their
function is to extend the heating surface of the boiler, that is to
increase its power and e
ffi
ciency by more e
ffi
cient heat recep-
tion from the
fl
ue gases.
2.2.12. Fire-
fi
ghter
Thermal safety valve protecting the fuel in the container against
ignition. In case of
fi
re glow reversing or getting to the feeder
pipe, the valve temperature sensor opens the valve and
fl
oods it
with water from a 5l container connected with a hose.
Summary of Contents for AGRO Multi 12
Page 1: ...Operation and maintenance manual for the boilers with feeder AGRO Multi...
Page 22: ......
Page 23: ......
Page 34: ......
Page 36: ...wer 13 12 2017 r...
Page 38: ......
Page 43: ...REGULATOR INSTRUCTION MANUAL ecoMAX 910R1...
Page 53: ...USER MANUAL OF CONTROLLER INSTALLATION AND SERVICE SETTINGS ecoMAX 910R1...
Page 59: ...23...
Page 83: ...47...
Page 86: ......
Page 114: ......
Page 115: ......