Certificate & Operation Manual

  

If in the course of the examination taken by the Manufacturer of the Product or its 
parts/components believed to be faulty, no faults have been detected, the Customer is 
responsible for compensation of the Manufacturer’s expenses related to the examination. 
Apart from the warranties mentioned above the Manufacturer does not provide any other 
warranties with regard to compatibility of a Product purchased with  software or products 
produced by other manufacturers as well as any warranties that this Product will fit for the 
purposes not stipulated in the Product’s in-line documentation. 
The warranty does not provide for any claims with regard to the technical specifications of 
the Product in case they are in compliance with those stated by the Manufacturer. The 
Manufacturer does not guarantee that the Product purchased will meet Customer’s 
requirements and expectations. 

PLEASE NOTE THAT PERCo PRODUCES TECHNICALLY SOPHISTICATED 

PRODUCTS THAT, IF NOT FAULTY, CANNOT BE RETURNED BACK IF BY SOME 

REASON THE CUSTOMER DEEMS THEM UNSATISFACTORY. 

 

 

The 

RP-15.2 proximity card reader

 is in conformity with the essential 

requirements of the EU’s Machinery, Low-Voltage and EMC 
Directives and carries the CE marking accordingly. 

 
 
 

 

14 

Summary of Contents for RP-15.2

Page 1: ...CERTIFICATE AND OPERATION MANUAL RP 15 2 Proximity Card Reader...

Page 2: ...Proximity Card Reader RP 15 2 Certificate and Operation Manual RU C RU 02 00073 4372 015 88226999 2013...

Page 3: ...e reader under Wiegand interface 6 5 CONFIGURATION 8 5 1 Indication setting 8 5 2 Changing the format of the output data 8 6 SAFETY REQUIREMENTS 9 7 INSTALLATION PROCEDURE 9 7 1 Features of installati...

Page 4: ...otects it from being damaged during transportation and storage The reader in the original package should be transported in closed freight containers or other closed type cargo transport units Storage...

Page 5: ...3 cm Controller connection interface Wiegand Output and operation signal voltage Logic 1 min 4 3 V Logic 0 max 0 4 V Distance between the reader and external controller max 150 m Connection cable sta...

Page 6: ...10302 H10304 and the production of EM Microelectronic Marin SA Each identifier has its own single code number of combinations more than 500 mlrd which is one time set at the stage of manufacture and c...

Page 7: ...possible not earlier than 200 ms after identifier leaves stable reception zone Two wires are used for transmission data 0 and data 1 Occurrence of logic level 0 on one of the wires signals the presen...

Page 8: ...in Figure 1 Control bit corresponds with the even parity for the next 12 bit data 2 Byte code 3 High order byte of card number 4 Low order byte of card number 5 Control bit corresponds with the odd pa...

Page 9: ...nit Table 1 Indication setting Control signals at a connection cable of a reader LED light in different modes at external control blue wire yellow wire single line double line 0 0 green orange 0 HZ gr...

Page 10: ...is made only upon power supply off Cable laying should be produced subject to electrical devices operation rules In case of faulty power supply reader operation is prohibited 7 INSTALLATION PROCEDURE...

Page 11: ...d level Measuring tape 2m 7 3 The cables used Recommended cable type for connection reader to external controller RAMCRO SA82BI T CABS8 EC 8C SEC SC W8ekw cross section 24AWG 18AWG it is prohibited to...

Page 12: ...to metal base plate Take off the metal base plate and fasten it with 4 screws from delivery set 5 If necessary to change the LED indication operation mode into double line two line control please cut...

Page 13: ...e Customer and their remedy are given in the table below Table 3 Troubleshooting guide Fault Possible cause Remedy At the power up the LED indicator of the reader does not light reader does not react...

Page 14: ...ce majeure circumstances natural disasters vandalism etc or defects as a result of external circumstances power surges electric discharge etc fuses accumulators galvanic elements and other components...

Page 15: ...his Product will fit for the purposes not stipulated in the Product s in line documentation The warranty does not provide for any claims with regard to the technical specifications of the Product in c...

Page 16: ...e of sale ____________________ 20___ ____________________________________ signature seal Cutting line Warranty Repair Coupon RP 15 2 Proximity card reader Serial number 5 3 7 Date of manufacture _____...

Page 17: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Page 18: ...www perco com...

Reviews: