background image

Certificate & Operation Manual

  

 

Attention

When mounting the reader please provide the cable bending radius of min. 10 mm at 
reader basis. 

8.  Run the cable, attach it and connect to external devices. Layout of reader connection 

to external devices under Wiegand interface is shown in Fig. 5. Switching the output 
data format is recommended to carry out directly at the junction of the regular reader 
cable with an extension cable (see section 5.2). 

 

 

 

Figure 5.  Connection layout of the reader to external devices  

under Wiegand interface  

 

8. TROUBLESHOOTING 

Possible faults that can be resolved by the Customer and their remedy are given in the 
table below: 

Table 3. Troubleshooting guide 

Fault  

Possible cause  

Remedy  

At the power-up the LED 
indicator of the reader does not
light, reader does not react on 
card presentation. 

No supply voltage to the reader

Check the accuracy of reader 
connection to power supply 

LED operation mode does not 
switch to «double line» 

Electric contact between  
«single-double» jumper wires 
or with ground bar 

Insulate «single-double» jumper 
wire ends (prior power off the 
reader) 

The required reader output 
data format does not switch on 

No electric contact between 
orange wire and necessary 
conductor according  Table 2 

Find the disconnection and reset 
the electric contact (prior power off 
the reader) 

If the fault is not cleared please contact the Manufacturer.  

 

12 

Summary of Contents for RP-15.2

Page 1: ...CERTIFICATE AND OPERATION MANUAL RP 15 2 Proximity Card Reader...

Page 2: ...Proximity Card Reader RP 15 2 Certificate and Operation Manual RU C RU 02 00073 4372 015 88226999 2013...

Page 3: ...e reader under Wiegand interface 6 5 CONFIGURATION 8 5 1 Indication setting 8 5 2 Changing the format of the output data 8 6 SAFETY REQUIREMENTS 9 7 INSTALLATION PROCEDURE 9 7 1 Features of installati...

Page 4: ...otects it from being damaged during transportation and storage The reader in the original package should be transported in closed freight containers or other closed type cargo transport units Storage...

Page 5: ...3 cm Controller connection interface Wiegand Output and operation signal voltage Logic 1 min 4 3 V Logic 0 max 0 4 V Distance between the reader and external controller max 150 m Connection cable sta...

Page 6: ...10302 H10304 and the production of EM Microelectronic Marin SA Each identifier has its own single code number of combinations more than 500 mlrd which is one time set at the stage of manufacture and c...

Page 7: ...possible not earlier than 200 ms after identifier leaves stable reception zone Two wires are used for transmission data 0 and data 1 Occurrence of logic level 0 on one of the wires signals the presen...

Page 8: ...in Figure 1 Control bit corresponds with the even parity for the next 12 bit data 2 Byte code 3 High order byte of card number 4 Low order byte of card number 5 Control bit corresponds with the odd pa...

Page 9: ...nit Table 1 Indication setting Control signals at a connection cable of a reader LED light in different modes at external control blue wire yellow wire single line double line 0 0 green orange 0 HZ gr...

Page 10: ...is made only upon power supply off Cable laying should be produced subject to electrical devices operation rules In case of faulty power supply reader operation is prohibited 7 INSTALLATION PROCEDURE...

Page 11: ...d level Measuring tape 2m 7 3 The cables used Recommended cable type for connection reader to external controller RAMCRO SA82BI T CABS8 EC 8C SEC SC W8ekw cross section 24AWG 18AWG it is prohibited to...

Page 12: ...to metal base plate Take off the metal base plate and fasten it with 4 screws from delivery set 5 If necessary to change the LED indication operation mode into double line two line control please cut...

Page 13: ...e Customer and their remedy are given in the table below Table 3 Troubleshooting guide Fault Possible cause Remedy At the power up the LED indicator of the reader does not light reader does not react...

Page 14: ...ce majeure circumstances natural disasters vandalism etc or defects as a result of external circumstances power surges electric discharge etc fuses accumulators galvanic elements and other components...

Page 15: ...his Product will fit for the purposes not stipulated in the Product s in line documentation The warranty does not provide for any claims with regard to the technical specifications of the Product in c...

Page 16: ...e of sale ____________________ 20___ ____________________________________ signature seal Cutting line Warranty Repair Coupon RP 15 2 Proximity card reader Serial number 5 3 7 Date of manufacture _____...

Page 17: ...PERCo Polytechnicheskaya str 4 block 2 194021 Saint Petersburg Russia Tel 7 812 247 04 64 E mail export perco com support perco com www perco com...

Page 18: ...www perco com...

Reviews: