Installation
2
0
2
0
-0
3
13
Connecting the Power Supply
Connect the operating voltage (10 VDC ... 30 VDC) to terminals 1 and 2 of the 4-pin plug X2 on
the interface module. In addition, note the label on the module.
The "Power" LED lights up green.
Terminal X2
Equipotential Bonding Connection
The connection to equipotential bonding occurs automatically when attaching to the DIN
mounting rail.
EtherNet/IP Communication Interface
This interface can be found on the interface module in the form of two 8-pin RJ45 sockets on
the bottom of the housing.
Insert the EtherNet/IP connector into one of the RJ45 socket(s) labeled "In" (cable from master)
or "Out" (further cable to the next EtherNet/IP slave).
Terminal
Description
1
UB+ (Pwr)
Operating voltage for interface module/
operating voltage for WCS read head
2
0 V (Pwr)
Ground interface module/ground sensor
3
not used
is not used
4
not used
is not used
Note
Ensure that the cable length to the neighboring EtherNet/IP participants is at
least 0.6 m.