background image

2193

65 

2017-02

28

VisuNet GMP DM

Operation

4.1.3

Menu 

Color

Sub menu

Description

Contrast

Adjust the contrast of the image

Brightness

Adjust the brightness of the image

Color Adjust

Adjust the value of red, green

,

 and blue

Color Temp

Adjust the color temperature

Auto Color

Run the auto config of the color

Back

Back to main menu

Summary of Contents for VisuNet GMP DM200 Series

Page 1: ...PROCESS AUTOMATION MANUAL VisuNet GMP DM200 Series Hardware Manual...

Page 2: ...rms of Delivery for Products and Services of the Electrical Indus try published by the Central Association of the Electrical Industry Zentralverband Elektrotechnik und Elektroindustrie ZVEI e V in its...

Page 3: ...10 2 4 3 Supply Voltage 24 V 11 2 4 4 Supply Voltage 120 230 V AC 11 2 5 Accessories 12 2 5 1 Keyboards 12 2 5 2 Pedestals 15 2 5 3 Wall arm versions 16 2 5 4 Wall bracket 16 2 5 5 Hole pattern of th...

Page 4: ...nu 26 4 1 2 Bright Contrast menu 27 4 1 3 Menu Color 28 4 1 4 Image menu 29 4 1 5 Tools menu 30 4 1 6 Input menu 31 4 1 7 Exit menu 32 5 Appendix 33 5 1 Chemical resistance of keyboard foil 33 5 2 Che...

Page 5: ...el Responsibility for planning assembly commissioning operation maintenance and dismounting lies with the plant operator The personnel must be appropriately trained and qualified in order to carry out...

Page 6: ...device must only be operated in the specified ambient temperature range and at the specified relative humidity without condensation The device is rated up to 2000 m and is intended to be used in a Pol...

Page 7: ...ion of mechanical components The VisuNet GMP product portfolio extends from simple direct monitors and remote monitor systems with Ethernet connection to a host to complete PCs available with single o...

Page 8: ...eel housing 304 1 4301 others on demand Degree of protection IP65 High end finish of all surfaces 2 2 Technical Data max 5m DM HOST VisuNet GMP DM219 VisuNet GMP DM221 VisuNet GMP DM222 General specif...

Page 9: ...nd optional trackball touch screen joystick Interface Interface type VGA or DVI Ambient conditions Ambient temperature 0 50 C 0 50 C 0 45 C Mechanical specifications Protection degree IP65 Installatio...

Page 10: ...7 GREEN_GND 12 IIC DATA 3 BLUE 8 BLUE_GND 13 HSYNC 4 not in use 9 5 V 14 VSYNC 5 GND 10 GND 15 IIC CLOCK 1 6 5 15 11 A B C D Phoenix DFK MSTB 2 5 4 GF 5 08 Ground connection M4 VG inter A face DVI in...

Page 11: ...k Picture Pin Signal 1 GND 2 GND 3 24 V DC 4 24 V DC 1 2 3 4 4 1 Picture Pin Signal 1 GND 2 GND 3 12 V DC 4 12 V DC 4 1 2 4 4 Supply Voltage 120 230 V AC 4 pin socket required for supply voltage conne...

Page 12: ...buttons below the touchpad assume the function of left and right mouse button Figure 2 4 Keyboard with touchpad TA3 K4 General specifications Type Keyboard with touchpad Supply Rated voltage via data...

Page 13: ...g Mechanical specifications Material anodized aluminium Polyester foil Mass 1 2 kg Dimensions 482 6 mm x 177 8 mm x 45 mm Cable length 1 8 m wire end ferrule TA3 K6 General specifications Type Keyboar...

Page 14: ...lative humidity max 85 non condensing Mechanical specifications Material anodized aluminium Polyester foil Mass 1 2 kg Dimensions 482 6 mm x 177 8 mm x 45 mm Cable length 1 8 m wire end ferrule TA3 K8...

Page 15: ...1000 560 750 420 225 350 540 2 3 4 5 6 7 1 Model number Description 1 PEDESTAL1 150 1V KP G T 304 Pedestal turnable approx 350 inclination of monitor 10 with pipe for keyboard 2 PEDESTAL1 150 1V KP G...

Page 16: ...ion of monitor 10 without pipe for keyboard 2 models available WALL ARM1 55 1V NT G F 304 fix WALL ARM1 55 1V NT G T 304 approx 350 turnable 2 WALL ARM1 55 0V KT G 304 Wall arm without inclination of...

Page 17: ...219365 2017 02 17 2 5 5 Hole pattern of the mounting versions Figure 2 10 Bottom attachment turnable fastening at front Figure 2 11 Bottom attachment fix mounted Figure 2 12 Wall bracket 1 2 9 9 40 A...

Page 18: ...r The VisuNet GMP has an option for connection of a handheld barcode reader The following products can be used at present Barcode handheld Powerscan PSCAN D 1D N0 R3 10 N The PSCAN D 1 consists of a b...

Page 19: ...mensions with Barcode handheld Dimensions VisuNet GMP DM 219 with Barcode handheld Dimensions VisuNet GMP DM 221 and DM 222 with Barcode handheld 682 29 5 187 97 131 74 152 85 152 13 450 73 740 29 5 1...

Page 20: ...VisuNet GMP DM Product Specifications 20 2 5 9 Holder for handheld barcode reader Dimensions 85 30 71 5 90 120 152 14 67 6 219365 2017 02...

Page 21: ...icensed for operation in confined spaces The cooling of the device does not require active components like CPU fan or water cooling systems For that reason there are no ventilation slots in the housin...

Page 22: ...vice and control cabinet Use cables with a minimum cross core section of 2 5 mm2 for power supply Turning on the VisuNet GMP 1 Connect the 4 pin plug with the 4 pin power supply socket at the back of...

Page 23: ...ng off the VisuNet GMP 1 Disconnect the device from the power supply 2 After that unscrew the power plug at the VisuNet GMP Note Use the VisuNet GMP only with safety low voltage protective extra low v...

Page 24: ...t the OSD menu press the button The OSD menu is divided in the following menu items Color Image Setting Position OSD Menu Language Misc Exit Picture Button Function Description Menu Menu selection 1 F...

Page 25: ...x Adjusting values 1 To adjust values e g brightness or contrast in a sub menu press the button and the button respectively 2 After adjusting the value quit the active dialog box by pressing the butto...

Page 26: ...VisuNet GMP DM Operation 4 1 1 Audio menu Menu item Name Description Volume Change the volume Mute Mute the audio Exit Quit the sub menu and return to the menu one lever higher Note The VisuNet GMP ha...

Page 27: ...ration 219365 2017 02 27 4 1 2 Bright Contrast menu Menu Item Name Description Brightness Decrease increase brightness Contrast Decrease increase contrast Exit Quit the sub menu and return to the menu...

Page 28: ...menu Description Contrast Adjust the contrast of the image Brightness Adjust the brightness of the image Color Adjust Adjust the value of red green and blue Color Temp Adjust the color temperature Aut...

Page 29: ...e menu Sub menu Description Clock Adjust the clock of the image Phase Adjust the phase of the image Gamma Adjust the gamma level of the image Sharpness Adjust the sharpness of the image Auto Adjust Ru...

Page 30: ...u item Name Description OSD Select more sub menus time horizontal vertical OSD menu direction exit Reset Reset to factory settings Sharpness Change sharpness Language Change language of OSD menu Exit...

Page 31: ...Net GMP DM Operation 219365 2017 02 31 4 1 6 Input menu Menu item Name Description VGA Activate VGA interface DVI Activate DVI interface Exit Quit the sub menu and return to the menu one lever higher...

Page 32: ...219365 2017 02 32 VisuNet GMP DM Operation 4 1 7 Exit menu...

Page 33: ...aligned polyester based material and therefore has a greater restistance to solvents It is physically resistant to pencil lead with a maximum hardness of 3HB The foil is resistant against the followi...

Page 34: ...line solutions Alkali carbonate Bichromate Potassium hydroxide 30 Acetonitrile sodium bisulfate potassium ferrocyanide Sodium hypochlorite 20 Various other substances Molecular chlorine Cresol phenol...

Page 35: ...that the following products caused slight discoloration Mustard Tomato juice Tomato ketchup Lemon juice No resistance Not resistant to concentrated mineral acids concentrated alkaline solutions High...

Page 36: ...hs com Worldwide Headquarters Pepperl Fuchs GmbH 68307 Mannheim Germany Tel 49 621 776 0 E mail info de pepperl fuchs com For the Pepperl Fuchs representative closest to you check www pepperl fuchs co...