Settings
Measurement Delay
This setting is used to determine the measurement delay for the measured values output by the
sensor. The measurement delay can be set to 25 ms, 12 ms, 6 ms, or 3 ms. A higher measure-
ment delay reduces the measurement noise; a smaller measurement delay improves the
response time. The factory default setting is 3 ms.
Measured Value Resolution
This parameter defines the resolution of the distance value output on the display and in the pro-
cess data. The settings "1 mm/bit" and "0.1 mm/bit" are available for selection. The factory
default setting is "1 mm/bit."
Offset
This value moves the zero point of the measurement. This enables multiple devices with differ-
ent positions to be set to identical distances. It does not change the absolute range. The mea-
sured value output is calculated from the sum of the absolute measured value and the signed
offset. The resulting measured value is used when testing the distance limits. The factory
default setting is 0 m.
Counting Direction
The counting direction setting can be used to invert the measurement's counting direction. The
device displays 0 mm at maximum distance. As the distances become smaller, the output value
increases. The measured value that is output is calculated from the difference between the limit
range and the real measured value. The factory default setting is "forward."
Smart Hold
The smart hold function reduces the noise of the distance value that is output at a standstill.
The measurement remains active. Changes to the distance value are output only if they exceed
an internal threshold value. The factory default setting is "active."
Error Substitute Value
This option defines which distance value is output by the device in the event of an error. You
can choose between the substitute value 0 mm, the substitute value -1 mm, and the last valid
measured value. The substitute value -1 mm is displayed as 999.999 m. If the device is unable
to determine a valid measured value when using the "last measured value" setting, the value
999.999 m is output. The factory default setting is "last measured value."
Error Delay
This setting defines a time delay for outputting an error. The delay occurs between the occur-
rence of an error and the signaling of the error using the error flag and signal display. The error
delay is specified in milliseconds. The factory default setting is "50 ms."
7.3.2
Menu Item Display
Display Language
You use this menu item to select the menu language. The available settings are German and
English. The factory default setting is "English."
Display Orientation
You use this menu item to change the orientation of the display. The setting options are 0
°
and
180
°
for overhead mounting. In this case, the function of the keys is rotated by 180
°
. The factory
default setting is "0
°
."
Note
If the resulting measured value is negative, an error is displayed by the device.
•
If this is the case, increase the offset.