2
02
2-
06
48
Inertial Measurement Unit IMUF99*B20
Parameter Table
0x7F
Param_AF_Gy
-
ro_z_SP2
7767 ... 57767
32767
2
For rotation rate z-axis:
The value of this switching point
parameter determines the Limit2,
exceeding or falling below it leads to
a change in the switching status for
the application flag. The value of
Limit2 can be chosen inde
-
pendently of Limit1.
0x80
Param_AF_Gy
-
ro_z_Logic
0, 1
0
1
For rotation rate z-axis:
This parameter determines which
value range of the Limits should be
displayed as the "active" value
range.
•
0 = low active:
In single point mode - if the value
falls below Limit1 (independent of
sign), AF is set to "low". If Limit1 is
exceeded (independent of sign), AF
is set to "high".
In window mode - If the value is
between Limit1 and Limit2, AF is set
to "low". If the value is outside of
Limit1 and Limit2, AF is set to
"high".
•
1 = high active:
In single point mode - if the value
falls below Limit1 (independent of
sign), AF is set to "high". If Limit1 is
exceeded (independent of sign), AF
is set to "low".
In window mode - If the value is
between Limit1 and Limit2, AF is set
to "high". If the value is outside of
Limit1 and Limit2, AF is set to "low".
0x81
Param_AF_In
-
cl_x_Mode
0, 1, 2
0
1
Just use it in combination with
INX/INY/INZ inclination setting.
Don't use it with ZYZ or zy'x'' incli
-
nation setting.
0 = deactivated; The status of the
application flag is statically "inac
-
tive". Set limits are ignored.
1 = single point; The status of the
application flag only switches
depending on Limit1. Limit2 is
ignored.
2 = windows; The range of values
between Limit1 and Limit2 deter
-
mines the status of the application
flag. The value for Limit1 and Limit2
can be selected independently of
each other.
Index Name
Valid values
Default value
Size
[bytes] Description