201
8-0
5
30
F99 Fusion Inertial Measurement Unit IMU360D-F99-B20
Parameter Table
0x2B PDO[6].Priority
0 ... 7
7
1
Priority of the PDO
0x2C PDO[7].PGN
0x00000 ...
0x3FFFF
0x0FF07
4
Process data PGN
0x2D PDO[7].Map
je Byte 0 ... 27
1)
25, 26, 27, 27 4
Defines the mapping of the
process data
0x2E PDO[7].Interval
0
…
65535
1
2
0 = no message is send
1...65535 = multiple of 10ms
0x2F PDO[7].Offset
0 ... 255
0
1
Offset for PDO interval to
equalize traffic demand
temporally.
Value = multiple of 10ms
0x30 PDO[7].Priority
0 ... 7
7
1
Priority of the PDO
SLOT Definition
0x31 Acc_SLOT[0].Factor
no limit
1000
2
Acceleration (Acc) SLOT value:
Factor
0x32 Acc_SLOT[0].Offset
no limit
0
2
Acceleration (Acc) SLOT value:
Offset
0x33 Reserved
-
-
-
Internal use only
0x34 Reserved
-
-
-
Internal use only
0x35 Gyro_SLOT[1].Factor
no limit
100
2
Rotation rate (Gyro) SLOT value:
Factor
0x36 Gyro_SLOT[1].Offset
no limit
0
2
Rotation rate (Gyro) SLOT value:
Offset
0x37 Reserved
-
-
-
Internal use only
0x38 Reserved
-
-
-
Internal use only
0x39 RotAcc_SLOT[2].Factor
no limit
1
2
Rotational Acceleration (RotAcc)
SLOT value: Factor
0x3A RotAcc_SLOT[2].Offset
no limit
0
2
Rotational Acceleration (RotAcc)
SLOT value: Offset
0x3B
...
0x40
Reserved
-
-
-
Internal use only
0x41 Grav_SLOT[4].Factor
no limit
1000
2
Gravity Vector (Grav) SLOT
value: Factor
0x42 Grav_SLOT[4].Offset
no limit
0
2
Gravity Vector (Grav) SLOT
value: Offset
0x43 Reserved
-
-
-
Internal use only
0x44 Reserved
-
-
-
Internal use only
0x45 LinAcc_SLOT[5].Factor
no limit
1000
2
Linear Acceleration (LinAcc)
SLOT value: Factor
0x46 LinAcc_SLOT[5].Offset
no limit
0
2
Linear Acceleration (LinAcc)
SLOT value: Offset
0x47 Reserved
-
-
-
Internal use only
0x48 Reserved
-
-
-
Internal use only
0x49 Eul_SLOT[6].Factor
no limit
100
2
Euler angle (Eul) SLOT value:
Factor
0x4A Eul_SLOT[6].Offset
no limit
0
2
Euler angle (Eul) SLOT value:
Offset
Index Name
Valid values
Default value
Size
[bytes] Description